Bleeding gastroesophageal varices: gastric vein embolization after partial portal decompression

Radiology. 1991 Jan;178(1):249-51. doi: 10.1148/radiology.178.1.1984312.

Abstract

Shunts that decompress the portal vein are effective in the treatment of bleeding esophageal varices. Use of large-caliber portacaval shunts, however, results in the complete decompression of the portal system and the risk of subsequent development of hepatic encephalopathy. Use of small-caliber portacaval shunts results in mild portal hypertension and less frequent hepatic encephalopathy but may increase the risk of recurrent bleeding. Thirty-three patients underwent angiography after partial decompression portacaval shunting (median trans-shunt pressures, 8 mm Hg). Embolization of residual varices, noted in 13 patients, was performed. Results included one complication with no sequelae and no bleeding a mean of 13 months after the procedure was performed. Trans-shunt embolization of esophageal varices effectively prevents bleeding varices after partial portal decompression.

MeSH terms

  • Embolization, Therapeutic*
  • Esophageal and Gastric Varices / therapy*
  • Female
  • Gastrointestinal Hemorrhage / therapy*
  • Humans
  • Male
  • Middle Aged
  • Portacaval Shunt, Surgical / methods*
  • Stomach / blood supply