Abstract
Purpose: To investigate the ability of a portable pupillometer, capable of 20-second binocular recordings of the swinging flashlight test (SFT), to detect relative afferent pupillary defects (rAPDs).
Methods: Pupillary response curves were recorded from both eyes in healthy volunteers (n = 22) with and without simulated rAPDs (using neutral density filters (NDFs)) and in abnormal patients (n = 24) with clinically graded rAPDs. The light stimulus (0.2 sec on and 1 sec off, or 2 sec on and 0.4 sec off) alternated between both eyes, simulating the SFT. Constriction amplitude (CA), constriction velocity (CV), and pupillary release were calculated by computer algorithm. In abnormal patients, NDFs were used to neutralize inter-eye differences.
Results: Significant correlation (Spearman's rho 0.71, 0.73) between NDF strength and absolute inter-eye differences was seen for CA and CV in simulated rAPDs. All abnormal patients (15/15) having rAPDs greater than 0.5 log units were distinguished from normals using either the upper bound of the one-sided 95% confidence interval (95% CI) value of CA or CV as determined from 22 healthy volunteers. Inter-eye variability in some normals prevented confident distinction of six abnormal patients with 0.3 log unit rAPDs. Using NDFs, subtle rAPDs were predicted in three patients having questionable rAPDs on clinical examination. CA and CV were more sensitive than pupillary release for all comparisons.
Conclusions: This binocular pupillometer identified all of our patients with > 0.5 log unit rAPDs. Using NDFs, all of our abnormal patients were accurately identified and their rAPDs quantified. Variability in some normals makes them indistinguishable from patients with subtle rAPDs.
Similar articles
-
A Novel Computerized Portable Pupillometer Detects and Quantifies Relative Afferent Pupillary Defects.Curr Eye Res. 2015;40(11):1120-7. doi: 10.3109/02713683.2014.980007. Epub 2015 Feb 6. Curr Eye Res. 2015. PMID: 25658805
-
Portable pupillography of the swinging flashlight test to detect afferent pupillary defects.Ophthalmology. 2000 Oct;107(10):1913-21; discussion 1922. doi: 10.1016/s0161-6420(00)00354-7. Ophthalmology. 2000. PMID: 11013198
-
Evaluation and calibration of a binocular infrared pupillometer for measuring relative afferent pupillary defect.J Neuroophthalmol. 2012 Jun;32(2):111-5. doi: 10.1097/WNO.0b013e31823f45e5. J Neuroophthalmol. 2012. PMID: 22246058
-
Neuro-ophthalmology of pupillary function--practical guidelines.J Neurol. 1998 Sep;245(9):573-83. doi: 10.1007/s004150050248. J Neurol. 1998. PMID: 9758294 Review.
-
Clinical applications of pupillography.J Neuroophthalmol. 2003 Mar;23(1):42-9. doi: 10.1097/00041327-200303000-00010. J Neuroophthalmol. 2003. PMID: 12616089 Review.
Cited by
-
Diagnostic accuracy of a modularized, virtual-reality-based automated pupillometer for detection of relative afferent pupillary defect in unilateral optic neuropathies.Front Ophthalmol (Lausanne). 2024 Sep 3;4:1396511. doi: 10.3389/fopht.2024.1396511. eCollection 2024. Front Ophthalmol (Lausanne). 2024. PMID: 39290775 Free PMC article.
-
Development and Implementation of a Handheld Pupillometer for Detection of Optic Neuropathies.Curr Eye Res. 2021 Sep;46(9):1432-1435. doi: 10.1080/02713683.2021.1878542. Epub 2021 Feb 5. Curr Eye Res. 2021. PMID: 33541152 Free PMC article.
-
Cross-sectional pupillographic evaluation of relative afferent pupillary defect in age-related macular degeneration.Medicine (Baltimore). 2016 Sep;95(39):e4978. doi: 10.1097/MD.0000000000004978. Medicine (Baltimore). 2016. PMID: 27684848 Free PMC article.
-
System and measurement method for binocular pupillometry to study pupil size variability.Biomed Eng Online. 2014 Jun 5;13:69. doi: 10.1186/1475-925X-13-69. Biomed Eng Online. 2014. PMID: 24899167 Free PMC article.
-
Three-year follow-up after unilateral subretinal delivery of adeno-associated virus in patients with Leber congenital Amaurosis type 2.Ophthalmology. 2013 Jun;120(6):1283-91. doi: 10.1016/j.ophtha.2012.11.048. Epub 2013 Mar 6. Ophthalmology. 2013. PMID: 23474247 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources