Quantitative and qualitative assessments of lung destruction and pulmonary functional loss from reduced-dose thin-section CT in pulmonary emphysema patients

Acad Radiol. 2010 Feb;17(2):163-8. doi: 10.1016/j.acra.2009.08.009. Epub 2009 Nov 11.

Abstract

Rationale and objectives: Academic and clinical interest in reducing radiation from computed tomography (CT) examinations has increased, and the purpose of this study was to determine the capabilities of reduced-dose multidetector-row CT (MDCT) in assessing lung destruction and pulmonary functional loss in pulmonary emphysema patients.

Materials and methods: Twenty-five consecutive smokers (15 men and 10 women; mean age 67.9 years; age range 49-86 years) underwent MDCT examinations using two different effective tube currents (standard-dose protocol [150 mAs] and reduced-dose protocol [50 mAs]). For quantitative and qualitative assessments of lung destruction in each subject, percentage of low attenuation emphysematous destruction areas (%LAAs) were computationally calculated, and visual emphysema scores (ESs) were determined for both protocols. To determine the capabilities for quantitative and qualitative assessments of lung destruction by using reduced-dose protocol, %LAAs and ESs of both protocols were compared statistically. To compare the capabilities for quantitative and qualitative assessments of pulmonary functional loss, %LAAs and ESs of both protocols were correlated with forced expiratory volume in 1 second (FEV1)/forced vital capacity (FVC).

Results: %LAAs and ESs had significant correlations between both protocols (%LAAs: r = 0.95, P < .001; ESs: r = 0.97, P < .001). The limits of agreement of %LAAs were -1.8 + or - 9.2%. The agreement of ESs between both protocols was substantial (kappa = 0.70). %LAAs and ESs of both protocols had significant correlations with FEV1/FVC (%LAAs of 150 mAs: r = -0.49, P < .05; %LAAs of 50 mAs: r = -0.44, P < .05; ESs of 150 mAs: r = -0.67, P < .001; ESs of 50 mAs: r = -0.66, P < .001).

Conclusion: Reduced-dose MDCT had a potential of substitution for standard-dose MDCT on the both assessments in pulmonary emphysema patients.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Body Burden*
  • Female
  • Humans
  • Image Enhancement / methods
  • Lung Injury / complications*
  • Lung Injury / diagnostic imaging*
  • Male
  • Middle Aged
  • Pulmonary Emphysema / complications*
  • Pulmonary Emphysema / diagnostic imaging*
  • Radiation Protection / methods
  • Radiographic Image Interpretation, Computer-Assisted / methods*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Tomography, X-Ray Computed / methods*