Effects of a short course of eszopiclone on continuous positive airway pressure adherence: a randomized trial
- PMID: 19920270
- DOI: 10.7326/0003-4819-151-10-200911170-00006
Effects of a short course of eszopiclone on continuous positive airway pressure adherence: a randomized trial
Abstract
Background: Adherence to short-term continuous positive airway pressure (CPAP) may predict long-term use. Unfortunately, initial CPAP intolerance may lead to poor adherence or abandonment of therapy.
Objective: To determine whether a short course of eszopiclone at the onset of therapy improves long-term CPAP adherence more than placebo in adults with obstructive sleep apnea.
Design: Parallel randomized, placebo-controlled trial from March 2007 to December 2008. Randomization, maintained and concealed centrally by pharmacy personnel, was computer-generated using fixed blocks of 10. Referring physicians, investigators, and patients were blinded to the treatment assignment until after the final data were collected. (ClinicalTrials.gov registration number: NCT00612157).
Setting: Academic sleep disorder center.
Patients: 160 adults (mean age, 45.7 years [SD, 7.3]; mean apnea-hypopnea index, 36.9 events/h [SD, 23]) with newly diagnosed obstructive sleep apnea initiating CPAP.
Intervention: Eszopiclone, 3 mg (n = 76), or matching placebo (n = 78) for the first 14 nights of CPAP.
Measurements: Use of CPAP was measured weekly for 24 weeks. Adherence to CPAP (primary outcome) and the rate of CPAP discontinuation and improvements in symptoms (secondary outcomes) were compared. Follow-up at 1, 3, and 6 months was completed by 150, 136, and 120 patients, respectively.
Results: Patients in the eszopiclone group used CPAP for 20.8% more nights (95% CI, 7.2% to 34.4%; P = 0.003), 1.3 more hours per night for all nights (CI, 0.4 to 2.2 hours; P = 0.005), and 1.1 more hours per night of CPAP use (CI, 0.2 to 2.1 hours; P = 0.019). The hazard ratio for discontinuation of CPAP was 1.90 (CI, 1.1 to 3.4; P = 0.033) times higher in the placebo group. Side effects were reported in 7.1% of patients and did not differ between groups.
Limitations: Patients had severe obstructive sleep apnea treated at a specialized sleep center with frequent follow-up; results may not be generalizable to different settings. Patients' tolerance to CPAP and their reasons for discontinuation were not assessed.
Conclusion: Compared with placebo, a short course of eszopiclone during the first 2 weeks of CPAP improved adherence and led to fewer patients discontinuing therapy.
Summary for patients in
-
Summaries for patients. Improving use of continuous positive airway pressure for obstructive sleep apnea.Ann Intern Med. 2009 Nov 17;151(10):I38. doi: 10.7326/0003-4819-151-10-200911170-00001. Ann Intern Med. 2009. PMID: 19920253 No abstract available.
Similar articles
-
Sedative use during continuous positive airway pressure titration improves subsequent compliance: a randomized, double-blind, placebo-controlled trial.Chest. 2009 Nov;136(5):1263-1268. doi: 10.1378/chest.09-0811. Epub 2009 Jun 30. Chest. 2009. PMID: 19567493 Clinical Trial.
-
A pilot study evaluating acute use of eszopiclone in patients with mild to moderate obstructive sleep apnea syndrome.Sleep Med. 2007 Aug;8(5):464-70. doi: 10.1016/j.sleep.2006.10.007. Epub 2007 May 18. Sleep Med. 2007. PMID: 17512799 Clinical Trial.
-
Summaries for patients. Improving use of continuous positive airway pressure for obstructive sleep apnea.Ann Intern Med. 2009 Nov 17;151(10):I38. doi: 10.7326/0003-4819-151-10-200911170-00001. Ann Intern Med. 2009. PMID: 19920253 No abstract available.
-
Effects of opioid, hypnotic and sedating medications on sleep-disordered breathing in adults with obstructive sleep apnoea.Cochrane Database Syst Rev. 2015 Jul 14;(7):CD011090. doi: 10.1002/14651858.CD011090.pub2. Cochrane Database Syst Rev. 2015. PMID: 26171909 Review.
-
Educational, supportive and behavioural interventions to improve usage of continuous positive airway pressure machines for adults with obstructive sleep apnoea.Cochrane Database Syst Rev. 2009 Apr 15;(2):CD007736. doi: 10.1002/14651858.CD007736. Cochrane Database Syst Rev. 2009. Update in: Cochrane Database Syst Rev. 2014 Jan 08;(1):CD007736. doi: 10.1002/14651858.CD007736.pub2 PMID: 19370691 Updated. Review.
Cited by
-
Sleep Deficiency in Obstructive Sleep Apnea.Sleep Med Clin. 2024 Dec;19(4):687-706. doi: 10.1016/j.jsmc.2024.08.002. Epub 2024 Sep 20. Sleep Med Clin. 2024. PMID: 39455186 Review.
-
Therapeutic adherence in patients with Obstructive Sleep Apnea Syndrome: a retrospective cohort study.Sleep Breath. 2024 Dec;28(6):2437-2443. doi: 10.1007/s11325-024-03097-y. Epub 2024 Aug 28. Sleep Breath. 2024. PMID: 39196316
-
Novel physiologic predictors of positive airway pressure effectiveness (NICEPAP) study: rationale, design and methods.Sleep Breath. 2024 Oct;28(5):2005-2015. doi: 10.1007/s11325-024-03099-w. Epub 2024 Jul 12. Sleep Breath. 2024. PMID: 38995327
-
Tackling obstructive sleep apnea with pharmacotherapeutics: expert guidance.Expert Opin Pharmacother. 2024 Jun;25(8):1019-1026. doi: 10.1080/14656566.2024.2365329. Epub 2024 Jun 24. Expert Opin Pharmacother. 2024. PMID: 38913403 Review.
-
The Present and Future of the Clinical Use of Physiological Traits for the Treatment of Patients with OSA: A Narrative Review.J Clin Med. 2024 Mar 13;13(6):1636. doi: 10.3390/jcm13061636. J Clin Med. 2024. PMID: 38541862 Free PMC article. Review.
Publication types
MeSH terms
Substances
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources