Abstract

Objectives: USPIO (ultrasmall superparamagnetic iron oxide contrast agent) MRI was a promising imaging modality in the detection of lymph-node metastases. And this meta-analysis is performed to compare the diagnostic accuracy of USPIO-enhanced MRI with non-enhanced MRI, USPIO-enhanced MRI in various body regions, and postcontrast alone for diagnosis of lymph-node metastases.

Methods: A comprehensive and systematic search was conducted in PubMed and EMBASE databases. After a systematic review of the studies, sensitivity, specificity, the Q* value and other measures of accuracy of USPIO-enhanced MRI in the diagnosis of lymph-node metastases were summarized. The overall test performance was based on summary receiver operating characteristic curves.

Results: Summary of ROC curve analysis for per-lymph-node data shows a pooled sensitivity of 0.90 (95% confidential interval [CI]: 0.88-0.91) and overall specificity of 0.96 (95% CI: 0.95-0.97) for USPIO-enhanced MRI, the Q* value for USPIO-enhanced MRI is 0.9195, diagnostic odds ratio (DOR) is 162.28 (95% CI: 91.82-286.81). Non-enhanced MRI had less overall sensitivity 0.39 (95% CI: 0.34-0.43) and specificity 0.90 (95% CI: 0.89-0.91), respectively, the Q* value for USPIO-enhanced MRI was 0.6321, DOR is 5.81 (95% CI: 3.64-9.82). Postcontrast MRI alone had sensitivity 0.85 (95% CI: 0.81-0.88) and specificity 0.93 (95% CI: 0.91-0.95), respectively, the Q* value for USPIO-enhanced MRI was 0.8976, DOR is 76.92 (95% CI: 34.21-172.93). There was significant heterogeneity for studies reporting enhanced MRI and non-enhanced MRI.

Conclusions: This meta-analysis has shown that USPIO-enhanced MRI offers higher diagnostic performance than conventional MRI, and is sensitive and specific for the detection of lymph-node metastases. Postcontrast images alone can equate diagnostic performance pre- and postcontrast MRI has achieved for lymph-node characterization. And the role of USPIO-enhanced MRI in clinical practice still needs to be investigated in future studies.

Publication types

  • Meta-Analysis
  • Systematic Review

MeSH terms

  • Contrast Media*
  • Dextrans*
  • Humans
  • Lymphatic Metastasis / diagnosis*
  • Magnetic Resonance Imaging / methods*
  • Magnetite Nanoparticles*
  • ROC Curve
  • Sensitivity and Specificity

Substances

  • Contrast Media
  • Dextrans
  • Magnetite Nanoparticles
  • ferumoxtran-10