A method for calibration of bone driver transducers to measure the mastoid impedance
- PMID: 20193750
- DOI: 10.1016/j.heares.2010.02.013
A method for calibration of bone driver transducers to measure the mastoid impedance
Abstract
When using bone vibrator transducers for clinical measurements, the transfer of energy from the bone driver depends on the impedance match between the driver and the load (human mastoid or otherwise) to which the driver will be applied. Current clinical calibration methods are incapable of quantifying this impedance mismatch, hence they fail to account for inter-subject variations of the energy transferred from the driver to the load. This study proposes a straightforward method for determining an absolute field calibration of a Radio Ear B71 bone driver, found by measuring the electrical input impedance of the transducer loaded by known masses. This absolute calibration is based upon a circuit model of the driver, describing it with three frequency-dependent parameters. Once these three parameters are known, measurements of the driver input voltage and current may be used to determine arbitrary mechanical load impedances (such as the in situ mastoid impedance), and thus the frequency dependence of the transmitted energy. The results of the proposed calibration method are validated by comparison with direct mechanical measurements using specialized equipment not available in the clinic, and a refined bone driver circuit model is proposed to better capture the observed behaviors.
Copyright (c) 2010 Elsevier B.V. All rights reserved.
Similar articles
-
Design and characterization of a high-power ultrasound driver with ultralow-output impedance.Rev Sci Instrum. 2009 Nov;80(11):114704. doi: 10.1063/1.3258207. Rev Sci Instrum. 2009. PMID: 19947748
-
Electro-acoustic performance of the new bone vibrator Radioear B81: a comparison with the conventional Radioear B71.Int J Audiol. 2015 May;54(5):334-40. doi: 10.3109/14992027.2014.980521. Epub 2014 Dec 18. Int J Audiol. 2015. PMID: 25519145
-
A system for generating a variable mechanical impedance and its use in an investigation of the electromechanical properties of the B71 audiometric bone vibrator.Br J Audiol. 1982 Feb;16(1):1-7. doi: 10.3109/03005368209081502. Br J Audiol. 1982. PMID: 7055651
-
Determination of acoustic impedances of multi matching layers for narrowband ultrasonic airborne transducers at frequencies <2.5 MHz - Application of a genetic algorithm.Ultrasonics. 2012 Jan;52(1):169-85. doi: 10.1016/j.ultras.2011.08.001. Epub 2011 Aug 17. Ultrasonics. 2012. PMID: 21893329
-
Verification of impedance measurements by a volumetric and electromechanical model.Scand Audiol Suppl. 1983;17:21-6. Scand Audiol Suppl. 1983. PMID: 6577553
Cited by
-
An objective bone conduction verification tool using a piezoelectric thin-film force transducer.Front Neurosci. 2022 Nov 17;16:1068682. doi: 10.3389/fnins.2022.1068682. eCollection 2022. Front Neurosci. 2022. PMID: 36466173 Free PMC article.
-
Methods for the calibration of bone conduction transducers at frequencies from 5 to 20 kHz.J Acoust Soc Am. 2022 May;151(5):2945. doi: 10.1121/10.0010381. J Acoust Soc Am. 2022. PMID: 35649943 Free PMC article.
-
Understanding Interdependencies between Mechanical Velocity and Electrical Voltage in Electromagnetic Micromixers.Micromachines (Basel). 2020 Jun 29;11(7):636. doi: 10.3390/mi11070636. Micromachines (Basel). 2020. PMID: 32610583 Free PMC article.
-
Pole-Zero Fitting for Transfer Function of Hearing-Aid Receiver: Evidence-Based Review.J Audiol Otol. 2018 Jul;22(3):111-119. doi: 10.7874/jao.2018.00073. Epub 2018 Jun 14. J Audiol Otol. 2018. PMID: 29890818 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources