Absence of prosthesis-patient mismatch with the new generation of Edwards stented aortic bioprosthesis

Interact Cardiovasc Thorac Surg. 2010 Jun;10(6):884-7; discussion 887-8. doi: 10.1510/icvts.2009.224915. Epub 2010 Mar 16.

Abstract

Prosthesis-patient mismatch (PPM) remains a controversial issue with the most recent stented biological valves. We analyzed the incidence of PPM after implantation of the Carpentier-Edwards Perimount Magna Ease aortic valve (PMEAV) bioprosthesis and assessed the early clinical outcome. Two hundred and seventy consecutive patients who received a PMEAV bioprosthesis between January 2007 and July 2008 were analyzed. Pre-, peri- and postoperative data were assessed and echocardiographic as well as clinical follow-up was performed. Mean age was 72+/-9 years, 168 (62.2%) were males. Fifty-seven patients (21.1%) were below 65 years of age. Absence of PPM, corresponding to an indexed effective orifice area >0.85 cm(2)/m(2), was 99.5%. Observed in-hospital mortality was 2.2% (six patients), with a predicted mortality according to the additive EuroSCORE of 7.6+/-3.1%. At echocardiographic assessment after a mean follow-up period of 150+/-91 days, mean transvalvular gradient was 11.8+/-4.8 mmHg (all valve sizes). No paravalvular leakage was seen. Nine patients died during follow-up. The Carpentier-Edwards PMEAV bioprosthesis shows excellent hemodynamic performance. This valve can be implanted in all sizes with an incidence of severe PPM below 0.5%.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Animals
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / physiopathology
  • Aortic Valve / surgery*
  • Aortic Valve Stenosis / diagnostic imaging
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / physiopathology
  • Aortic Valve Stenosis / surgery*
  • Bioprosthesis*
  • Echocardiography, Doppler
  • Female
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation*
  • Heart Valve Prosthesis Implantation / mortality
  • Heart Valve Prosthesis*
  • Hemodynamics
  • Hospital Mortality
  • Humans
  • Male
  • Middle Aged
  • Patient Selection
  • Prosthesis Design
  • Stents*
  • Swine
  • Time Factors
  • Treatment Outcome