Abstract

Consonant production was investigated in 29 children participating in the federal Food and Drug Administration's clinical trials of the Nucleus WSP-III cochlear implant. Speech samples were collected preimplant and 1 year postimplant. A significantly greater number of children produced stop, nasal, fricative, and glide consonants postimplant. Voiced stop consonants were used by more children than the voiceless cognates; however, voiceless fricatives were used more than voiced fricatives. Visible places of articulation were used more frequently than less visible places of articulation. Comparisons to Smith's data (J Speech Hear Res 1975;18:795-811) revealed qualitative similarities but postimplant, quantitative differences were observed. Post hoc analyses of the data revealed some sounds were influenced more by an implant than other sounds and suggest the role of an implant upon spontaneous speech is complex.