N4ITK: improved N3 bias correction
- PMID: 20378467
- PMCID: PMC3071855
- DOI: 10.1109/TMI.2010.2046908
N4ITK: improved N3 bias correction
Abstract
A variant of the popular nonparametric nonuniform intensity normalization (N3) algorithm is proposed for bias field correction. Given the superb performance of N3 and its public availability, it has been the subject of several evaluation studies. These studies have demonstrated the importance of certain parameters associated with the B-spline least-squares fitting. We propose the substitution of a recently developed fast and robust B-spline approximation routine and a modified hierarchical optimization scheme for improved bias field correction over the original N3 algorithm. Similar to the N3 algorithm, we also make the source code, testing, and technical documentation of our contribution, which we denote as "N4ITK," available to the public through the Insight Toolkit of the National Institutes of Health. Performance assessment is demonstrated using simulated data from the publicly available Brainweb database, hyperpolarized (3)He lung image data, and 9.4T postmortem hippocampus data.
Figures
Similar articles
-
Intensity inhomogeneity correction using N3 on mouse brain magnetic resonance microscopy.J Neuroimaging. 2013 Oct;23(4):502-7. doi: 10.1111/jon.12041. Epub 2013 Jul 29. J Neuroimaging. 2013. PMID: 23895576
-
A fast and automatic method to correct intensity inhomogeneity in MR brain images.Med Image Comput Comput Assist Interv. 2006;9(Pt 2):324-31. doi: 10.1007/11866763_40. Med Image Comput Comput Assist Interv. 2006. PMID: 17354788
-
An improved variational level set method for MR image segmentation and bias field correction.Magn Reson Imaging. 2013 Apr;31(3):439-47. doi: 10.1016/j.mri.2012.08.002. Epub 2012 Dec 7. Magn Reson Imaging. 2013. PMID: 23219273
-
Correction of bias field in MR images using singularity function analysis.IEEE Trans Med Imaging. 2005 Aug;24(8):1067-85. doi: 10.1109/TMI.2005.852066. IEEE Trans Med Imaging. 2005. PMID: 16092338
-
Prospective motion correction in brain imaging: a review.Magn Reson Med. 2013 Mar 1;69(3):621-36. doi: 10.1002/mrm.24314. Epub 2012 May 8. Magn Reson Med. 2013. PMID: 22570274 Review.
Cited by
-
Multi-stage semi-supervised learning enhances white matter hyperintensity segmentation.Front Comput Neurosci. 2024 Oct 22;18:1487877. doi: 10.3389/fncom.2024.1487877. eCollection 2024. Front Comput Neurosci. 2024. PMID: 39502452 Free PMC article.
-
3D MRI of explanted sheep hearts with submillimeter isotropic spatial resolution: comparison between diffusion tensor and structure tensor imaging.MAGMA. 2021 Oct;34(5):741-755. doi: 10.1007/s10334-021-00913-4. Epub 2021 Feb 27. MAGMA. 2021. PMID: 33638739 Free PMC article.
-
A novel rhesus macaque model of Huntington's disease recapitulates key neuropathological changes along with motor and cognitive decline.Elife. 2022 Oct 7;11:e77568. doi: 10.7554/eLife.77568. Elife. 2022. PMID: 36205397 Free PMC article.
-
Assessment of Thigh MRI Radiomics and Clinical Characteristics for Assisting in Discrimination of Juvenile Dermatomyositis.J Clin Med. 2022 Nov 13;11(22):6712. doi: 10.3390/jcm11226712. J Clin Med. 2022. PMID: 36431189 Free PMC article.
-
Deep learning-based BMI inference from structural brain MRI reflects brain alterations following lifestyle intervention.Hum Brain Mapp. 2024 Feb 15;45(3):e26595. doi: 10.1002/hbm.26595. Hum Brain Mapp. 2024. PMID: 38375968 Free PMC article. Clinical Trial.
References
-
- Belaroussi B, Milles J, Carme S, Zhu YM, Benoit-Cattin H. Intensity nonuniformity correction in MRI: Existing methods and their validation. Med Image Anal. 2006 Apr;10(2):234–246. - PubMed
-
- Vovk U, Pernus F, Likar B. A review of methods for correction of intensity inhomogeneity in MRI. IEEE Trans Med Imag. 2007 Mar;26(3):405–421. - PubMed
-
- Sled JG, Zijdenbos AP, Evans AC. A nonparametric method for automatic correction of intensity nonuniformity in MRI data. IEEE Trans Med Imag. 1998 Feb;17(1):87–97. - PubMed
-
- Arnold JB, Liow JS, Schaper KA, Stern JJ, Sled JG, Shattuck DW, Worth AJ, Cohen MS, Leahy RM, Mazziotta JC, Rottenberg A. Qualitative and quantitative evaluation of six algorithms for correcting intensity nonuniformity effects. Neuroimage. 2001 May;13(5):931–943. - PubMed
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
