. 2010 Oct;19(5):430-4.
doi: 10.1136/qshc.2009.032839. Epub 2010 Apr 27.

The impact of traditional and smart pump infusion technology on nurse medication administration performance in a simulated inpatient unit

Affiliations

The impact of traditional and smart pump infusion technology on nurse medication administration performance in a simulated inpatient unit

P L Trbovich et al. Qual Saf Health Care. 2010 Oct.

Abstract

Objective: Assess the impact of infusion pump technologies (traditional pump vs smart pump vs smart pump with barcode) on nurses' ability to safely administer intravenous medications.

Design: Experimental study with a repeated measures design.

Setting: High-fidelity simulated inpatient unit.

Results: The nurses remedied 60% of "wrong drug" errors. This rate did not vary as a function of pump type. The nurses remedied "wrong patient" errors more often when using the barcode pump (88%) than when using the traditional pump (46%) or the smart pump (58%) (Cochran Q=14.36; p<0.05). The number of nurses who remedied "wrong dose hard limit" errors was higher when using the smart pump (75%) and the barcode pump (79%) than when using the traditional pump (38%) (Cochran Q=12.13; p<0.003). Conversely, there was no difference in remediation of "wrong dose soft limit" errors across pump types. The nurses' pump programming was less accurate when mathematical conversions were required. Success rates on secondary infusions were low (55.6%) and did not vary as a function of pump type.

Conclusions: These findings indicate that soft (changeable) limits in smart infusion pumps had no significant effect in preventing dosing errors. Provided that smart pumps are programmed with hard (unchangeable) limits, they can prevent dosing errors, thereby increasing patient safety. Until barcode pumps are integrated with other systems within the medication administration process, their role in enhancing patient safety will be limited. Further improvements to pump technologies are needed to mitigate risks associated with intravenous infusions, particularly secondary infusions.

PubMed Disclaimer

Conflict of interest statement

Competing interests: None.

Figures

Figure 1
Figure 1
Example of programming an intermittent infusion.

Similar articles

Cited by

References

    1. Leape LL, Brennan TA, Laird NM, et al. The nature of adverse events in hospitalized patients: results from the Harvard Medical Practice Study II. N Engl J Med 1991;324:377–84 - PubMed
    1. Kinnealey E, Fishman G, Sims N, et al. Infusion pumps with “drug libraries” at the point of care—a common solution for safer drug delivery 2003. http://www.npsf.org/download/Kinnealy.pdf (accessed 22 Dec 2008).
    1. Ross LM, Wallace J, Paton JY. Medication errors in a paediatric teaching hospital in the UK: five years operational experience. Arch Dis Child 2001;83:492–7 - PMC - PubMed
    1. Kaushal R, Bates DW, Landrigan C, et al. Medication errors and adverse drug events in pediatric inpatients. JAMA 2001;285:2114–20 - PubMed
    1. Tourville J. Automation and error reduction: how technology is helping Children's Medical Center of Dallas reach zero-error tolerance. US Pharmacist 2003;28:80–6

Publication types