Composite pre-heating: effects on marginal adaptation, degree of conversion and mechanical properties

Dent Mater. 2010 Sep;26(9):908-14. doi: 10.1016/j.dental.2010.03.023. Epub 2010 Jun 16.

Abstract

Objectives: This study evaluated the effect of composite pre-polymerization temperature and energy density on the marginal adaptation (MA), degree of conversion (DC), flexural strength (FS), and polymer cross-linking (PCL) of a resin composite (Filtek Z350, 3M/ESPE).

Methods: For MA, class V cavities (4 mm x 2 mm x 2 mm) were prepared in 40 bovine incisors. The adhesive system Adper Single Bond 2 (3M/ESPE) was applied. Before being placed in the cavities, the resin composite was either kept at room-temperature (25 degrees C) or previously pre-heated to 68 degrees C in the Calset device (AdDent Inc., Danbury, CT, USA). The composite was then light polymerized for 20 or 40s at 600 mW/cm(2) (12 or 24 J/cm(2), respectively). The percentage of gaps was analyzed by scanning electron microscopy, after sectioning the restorations and preparing epoxy resin replicas. DC (n=3) was obtained by FT-Raman spectroscopy on irradiated and non-irradiated composite surfaces. FS (n=10) was measured by the three-point-bending test. KHN (n=6) was measured after 24 h dry storage and again after immersion in 100% ethanol solution for 24h, to calculate PCL density. Data were analyzed by appropriate statistical analyses.

Results: The pre-heated composite showed better MA than the room-temperature groups. A higher number of gaps were observed in the room-temperature groups, irrespective of the energy density, mainly in the axial wall (p<0.05). Composite pre-heating and energy density did not affect the DC, FS and PCL (p>0.05).

Significance: Pre-heating the composite prior to light polymerization similar in a clinical situation did not alter the mechanical properties and monomer conversion of the composite, but provided enhanced composite adaptation to cavity walls.

MeSH terms

  • Analysis of Variance
  • Animals
  • Cattle
  • Composite Resins / chemistry*
  • Dental Marginal Adaptation*
  • Dental Stress Analysis
  • Hardness
  • Hot Temperature
  • Light-Curing of Dental Adhesives*
  • Materials Testing
  • Pliability
  • Polymerization
  • Polymers / chemistry
  • Random Allocation

Substances

  • Composite Resins
  • Polymers
  • filtek Z350