Contact lens deposits, adverse responses, and clinical ocular surface parameters

Optom Vis Sci. 2010 Sep;87(9):669-74. doi: 10.1097/OPX.0b013e3181ea1848.

Abstract

Purpose: To correlate clinical responses during contact lens wear with the amount of protein or cholesterol extracted from lenses after wear.

Methods: Clinical parameters, including adverse response rates and corneal staining, and symptomatology rating during lens wear were collected from a series of clinical tests comprising four different silicone hydrogel lenses with four different multipurpose solutions. To test for correlates, the amount of total protein or cholesterol extracted from lenses after daily wear were compared statistically to clinical parameters.

Results: The amount of protein (p = 0.008) or cholesterol (p = 0.01) extracted from lenses was higher for those subjects who showed solution-induced corneal staining. Amount of protein extracted was correlated (p < 0.01) with conjunctival staining (R = -0.23), lens front surface wetting (r = 0.14), and lens fit tightness (R = -0.20). These clinical parameters accounted for 48% of lens protein deposition. The amount of cholesterol extracted from lenses was much more weakly associated with clinical variables. Amount of protein or cholesterol extracted from lenses was not associated with the production of any corneal infiltrative or mechanical adverse event during wear and was only very weakly correlated with insertion comfort of lenses.

Conclusions: These results suggest that there may be no physiologically relevant consequence of cholesterol depositing on silicone hydrogel lenses. The amount of protein that deposits onto silicone hydrogel lenses during wear may have more affect on lens performance on-eye. However, the correlations were generally small and may still not indicate any causative relevant physiological response. Further work is required to determine whether there is any direct causative effect to support these correlative findings.

Publication types

  • Comparative Study
  • Controlled Clinical Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Cholesterol / analysis*
  • Conjunctiva / chemistry
  • Contact Lenses, Hydrophilic / adverse effects*
  • Cornea / chemistry
  • Eye Proteins / analysis*
  • Humans
  • Hydrogel, Polyethylene Glycol Dimethacrylate
  • Silicones
  • Staining and Labeling

Substances

  • Eye Proteins
  • Silicones
  • Hydrogel, Polyethylene Glycol Dimethacrylate
  • Cholesterol