Preparation of radiochemically pure (79)Se and highly precise determination of its half-life
- PMID: 20627600
- DOI: 10.1016/j.apradiso.2010.05.006
Preparation of radiochemically pure (79)Se and highly precise determination of its half-life
Abstract
Reliable knowledge of the (79)Se half-life is crucial, e.g. for the safety assessments of final repositories for nuclear waste. However, a literature survey reveals an inconsistent picture, indicating remarkably difficult experimental conditions. This work reports a new value of 3.27(8) × 10(5) a for the half-life of (79)Se. The uncertainty is less than half of the latest published result. The sample was prepared radiochemically pure from a reprocessing solution by exploitation of reductive deposition on Cu, anion exchange chromatography and sublimation. The specific activity was determined by inductively coupled plasma optical emission spectrometry (ICP-OES) and liquid scintillation counting (LSC). Hydride generation multicollector inductively coupled plasma mass spectrometry (HG-MC-ICP-MS) was applied for the establishment of the isotopic composition.
Copyright 2010 Elsevier Ltd. All rights reserved.
Similar articles
-
A new determination of 79Se half-life.Appl Radiat Isot. 2007 Mar;65(3):355-64. doi: 10.1016/j.apradiso.2006.09.009. Epub 2006 Dec 8. Appl Radiat Isot. 2007. PMID: 17157511
-
Isotope ratio determination in boron analysis.Biol Trace Elem Res. 1998 Winter;66(1-3):39-53. doi: 10.1007/BF02783124. Biol Trace Elem Res. 1998. PMID: 10050906 Review.
-
Experimental half-life determination of ¹⁷⁶Lu.Appl Radiat Isot. 2013 Nov;81:140-5. doi: 10.1016/j.apradiso.2013.03.033. Epub 2013 Mar 22. Appl Radiat Isot. 2013. PMID: 23570954
-
Searching the most appropriate sample pretreatment for the elemental analysis of wines by inductively coupled plasma-based techniques.J Agric Food Chem. 2008 Jul 9;56(13):4943-54. doi: 10.1021/jf800286y. Epub 2008 Jun 14. J Agric Food Chem. 2008. PMID: 18553915
-
Recent applications of continuous flow chemical vapor and hydride generation (CVG, HG) coupled to plasma-based optical emission spectrometry (ICP OES, MIP OES).Talanta. 2022 Jun 1;243:123372. doi: 10.1016/j.talanta.2022.123372. Epub 2022 Mar 9. Talanta. 2022. PMID: 35287019 Review.
Cited by
-
Liquid-liquid extraction of selenium (IV) ions from hydrochloric acid solution using Aliquat 336 dissolved in kerosene.BMC Chem. 2024 Sep 28;18(1):186. doi: 10.1186/s13065-024-01288-y. BMC Chem. 2024. PMID: 39342227 Free PMC article.
-
The half-life re-measured: consolidating the chronometer for events in the early Solar System.Sci Rep. 2024 Aug 1;14(1):17436. doi: 10.1038/s41598-024-64104-6. Sci Rep. 2024. PMID: 39090187 Free PMC article.
LinkOut - more resources
Full Text Sources
