Strut coverage and vessel wall response to a new-generation paclitaxel-eluting stent with an ultrathin biodegradable abluminal polymer: Optical Coherence Tomography Drug-Eluting Stent Investigation (OCTDESI)

Circ Cardiovasc Interv. 2010 Aug;3(4):367-75. doi: 10.1161/CIRCINTERVENTIONS.110.950154. Epub 2010 Jul 20.

Abstract

Background: Polymer-coated drug-eluting stents are effective in preventing restenosis but have been associated with delayed healing and incomplete strut coverage. It is unknown whether paclitaxel-eluting stents (PES) with minimal biodegradable abluminal coating enhances strut coverage while preventing neointimal hyperplasia. Using optical coherence tomography (OCT) as a primary imaging modality, we assessed the proportion of uncovered struts at 6-month follow-up in PES coated with durable versus ultrathin (<1 microm) biodegradable abluminal polymers.

Methods and results: In this pilot trial, 60 patients with de novo lesions (< or =25 mm) in native coronary vessels were randomly assigned to receive either TAXUS Liberté PES or JACTAX PES, a Liberté stent with polymer deposited abluminally as microdots (JACTAX HD: 9.2 microg each of polymer and paclitaxel per 16-mm stent; JACTAX LD: 5 microg each). OCT follow-up occurred at 6 months with clinical follow-up through 1 year. The primary end point was percent uncovered struts by OCT. An independent core laboratory blinded to stent assignment analyzed images. The 6-month rate of uncovered struts per patient was 5.3+/-14.7% for TAXUS Liberté, 7.0+/-12.2% for JACTAX HD, and 4.6+/-7.3% for JACTAX LD (P=0.81); percent malapposed struts was 1.4+/-4.4%, 0.8+/-1.9%, and 1.1+/-2.8%, respectively (P=0.86). Strut-level intimal thickness was 0.20+/-0.10, 0.22+/-0.15, and 0.24+/-0.15 mm (P=0.64); percent volume obstruction by OCT was 22.2+/-12.8, 22.5+/-16.2, and 25.8+/-15.2 (P=0.69). There were no deaths, Q-wave myocardial infarctions, or stent thromboses through 1 year.

Conclusions: JACTAX PES with an ultrathin microdot biodegradable abluminal polymer did not result in improved strut coverage at 6 months compared with TAXUS Liberté.

Clinical trial registration: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00776204.

Publication types

  • Comparative Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Absorbable Implants / adverse effects*
  • Aged
  • Angioplasty / adverse effects*
  • Coronary Artery Disease / diagnosis
  • Coronary Artery Disease / pathology
  • Coronary Artery Disease / physiopathology
  • Coronary Restenosis / diagnostic imaging
  • Coronary Restenosis / etiology*
  • Coronary Restenosis / prevention & control
  • Drug-Eluting Stents / adverse effects
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Middle Aged
  • Paclitaxel / therapeutic use*
  • Pilot Projects
  • Polymers / metabolism
  • Postoperative Complications*
  • Tomography, Optical Coherence
  • Ultrasonography, Interventional

Substances

  • Polymers
  • Paclitaxel

Associated data

  • ClinicalTrials.gov/NCT00776204