Quantifying colocalization by correlation: the Pearson correlation coefficient is superior to the Mander's overlap coefficient
- PMID: 20653013
- DOI: 10.1002/cyto.a.20896
Quantifying colocalization by correlation: the Pearson correlation coefficient is superior to the Mander's overlap coefficient
Abstract
The Pearson correlation coefficient (PCC) and the Mander's overlap coefficient (MOC) are used to quantify the degree of colocalization between fluorophores. The MOC was introduced to overcome perceived problems with the PCC. The two coefficients are mathematically similar, differing in the use of either the absolute intensities (MOC) or of the deviation from the mean (PCC). A range of correlated datasets, which extend to the limits of the PCC, only evoked a limited response from the MOC. The PCC is unaffected by changes to the offset while the MOC increases when the offset is positive. Both coefficients are independent of gain. The MOC is a confusing hybrid measurement, that combines correlation with a heavily weighted form of co-occurrence, favors high intensity combinations, downplays combinations in which either or both intensities are low and ignores blank pixels. The PCC only measures correlation. A surprising finding was that the addition of a second uncorrelated population can substantially increase the measured correlation, demonstrating the importance of excluding background pixels. Overall, since the MOC is unresponsive to substantial changes in the data and is hard to interpret, it is neither an alternative to nor a useful substitute for the PCC. The MOC is not suitable for making measurements of colocalization either by correlation or co-occurrence.
Similar articles
-
Quantifying colocalization: The case for discarding the Manders overlap coefficient.Cytometry A. 2021 Sep;99(9):910-920. doi: 10.1002/cyto.a.24336. Epub 2021 Mar 30. Cytometry A. 2021. PMID: 33720475
-
Colocalization analysis in fluorescence microscopy.Methods Mol Biol. 2013;931:97-109. doi: 10.1007/978-1-62703-056-4_5. Methods Mol Biol. 2013. PMID: 23026999
-
Replicate-based noise corrected correlation for accurate measurements of colocalization.J Microsc. 2008 Apr;230(Pt 1):121-33. doi: 10.1111/j.1365-2818.2008.01967.x. J Microsc. 2008. PMID: 18387047
-
Colocalization analysis yields superior results after image restoration.Microsc Res Tech. 2004 Jun 1;64(2):103-12. doi: 10.1002/jemt.20066. Microsc Res Tech. 2004. PMID: 15352081 Review.
-
Advances in image correlation spectroscopy: measuring number densities, aggregation states, and dynamics of fluorescently labeled macromolecules in cells.Cell Biochem Biophys. 2007;49(3):141-64. doi: 10.1007/s12013-007-9000-5. Epub 2007 Oct 2. Cell Biochem Biophys. 2007. PMID: 17952641 Review.
Cited by
-
Super-resolution laser probing of integrated circuits using algorithmic methods.Nat Commun. 2022 Sep 2;13(1):5155. doi: 10.1038/s41467-022-32724-z. Nat Commun. 2022. PMID: 36055983 Free PMC article.
-
Comparison of profile similarity measures for genetic interaction networks.PLoS One. 2013 Jul 10;8(7):e68664. doi: 10.1371/journal.pone.0068664. Print 2013. PLoS One. 2013. PMID: 23874711 Free PMC article.
-
Pivotal role of mitochondrial Na⁺₋Ca²⁺ exchange in antigen receptor mediated Ca²⁺ signalling in DT40 and A20 B lymphocytes.J Physiol. 2012 Feb 1;590(3):459-74. doi: 10.1113/jphysiol.2011.222927. Epub 2011 Dec 12. J Physiol. 2012. PMID: 22155933 Free PMC article.
-
ATRA modulates mechanical activation of TGF-β by pancreatic stellate cells.Sci Rep. 2016 Jul 4;6:27639. doi: 10.1038/srep27639. Sci Rep. 2016. PMID: 27375161 Free PMC article.
-
Measuring Nanoscale Distances by Structured Illumination Microscopy and Image Cross-Correlation Spectroscopy (SIM-ICCS).Sensors (Basel). 2021 Mar 12;21(6):2010. doi: 10.3390/s21062010. Sensors (Basel). 2021. PMID: 33809144 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources