Making existing technology safer in healthcare
- PMID: 20693212
- DOI: 10.1136/qshc.2009.038539
Making existing technology safer in healthcare
Abstract
Background: Technology, equipment and medical devices are vital for effective healthcare throughout the world but are associated with risks. These risks include device failure, inappropriate use, insufficient user-training and inadequate inspection and maintenance. Further risks within the developing world include challenging conditions of temperature and humidity, poor infrastructure, poorly trained service providers, limited resources and supervision, and inappropriately complex equipment being supplied without backup training for its use or maintenance.
Methods: This document is the product of an expert working group established by WHO Patient Safety to define the measures being taken to reduce these risks. It considers how the provision of safer technology services worldwide is being enhanced in three ways: through non-punitive and open reporting systems of technology-related adverse events and near-misses, with classification and investigation; through healthcare quality assessment, accreditation and certification; and by the investigation of how appropriate design and an understanding of the conditions of use and associated human factors can improve patient safety.
Results and discussion: Many aspects of these steps remain aspirational for developing countries, where highly disparate needs and a vast range of technology-related problems exist. Here, much greater emphasis must be placed on failsafe, durable and user-friendly design--examples of which are described.
Similar articles
-
[Quality of health care, accreditation, and health technology assessment in Croatia: role of agency for quality and accreditation in health].Acta Med Croatica. 2010 Dec;64(5):425-34. Acta Med Croatica. 2010. PMID: 21692267 Croatian.
-
Medical device problem reporting for the betterment of healthcare.Health Devices. 1998 Aug;27(8):277-92. Health Devices. 1998. PMID: 9743900
-
ACCF/AHA methodology for the development of quality measures for cardiovascular technology: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Performance Measures.J Am Coll Cardiol. 2011 Sep 27;58(14):1517-38. doi: 10.1016/j.jacc.2011.07.007. Epub 2011 Aug 29. J Am Coll Cardiol. 2011. PMID: 21880456
-
Improving patient care by reporting problems with medical devices.CRNA. 1998 Nov;9(4):139-56. CRNA. 1998. PMID: 9866489 Review.
-
ACCF/AHA methodology for the development of quality measures for cardiovascular technology: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Performance Measures.Circulation. 2011 Sep 27;124(13):1483-502. doi: 10.1161/CIR.0b013e31822935fc. Epub 2011 Aug 29. Circulation. 2011. PMID: 21875906
Cited by
-
Leaving patients to their own devices? Smart technology, safety and therapeutic relationships.BMC Med Ethics. 2018 Mar 6;19(1):18. doi: 10.1186/s12910-018-0255-8. BMC Med Ethics. 2018. PMID: 29510750 Free PMC article.
-
Design, development and implementation of a surgical simulation pathway curriculum for biliary disease.Surg Endosc. 2015 Jan;29(1):68-76. doi: 10.1007/s00464-014-3661-0. Epub 2014 Jun 25. Surg Endosc. 2015. PMID: 24962865
-
Classifying health information technology patient safety related incidents - an approach used in Wales.Appl Clin Inform. 2012 Jun 27;3(2):248-57. doi: 10.4338/ACI-2012-03-RA-0010. Print 2012. Appl Clin Inform. 2012. PMID: 23646074 Free PMC article. Review.
-
The case for randomized controlled trials to assess the impact of clinical information systems.J Am Med Inform Assoc. 2011 Mar-Apr;18(2):173-80. doi: 10.1136/jamia.2010.010306. Epub 2011 Jan 26. J Am Med Inform Assoc. 2011. PMID: 21270132 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical