In vitro detection of secondary caries associated with composite restorations on approximal surfaces using laser fluorescence

Oper Dent. 2010 Sep-Oct;35(5):564-71. doi: 10.2341/09-332-L.

Abstract

This study evaluated the performance of the DIAGNOdent pen laser fluorescence device (LFpen) in comparison with visual examination (VE), bitewing radiographs (BW) and visual examination combined with bitewing radiographs (VEBW) in detecting secondary approximal caries associated with composite restorations. In total, 60 approximal surfaces from 43 permanent molars with composite restorations were assessed twice by two examiners using the LFpen, VE, BW and VEBW. After histological preparation and hardness measurements, the sample was assigned to either a crown or root caries group, depending on the location of the lesions as the gold standard. For crown caries at D1, the highest values of specificity and sensitivity were observed for the LFpen at a cutoff value of 18 (1.00) and for the VEBW (0.89). At D3 (cutoff of 30), the LFpen showed the highest values of sensitivity and specificity. For root caries, the LFpen and VEBW showed the highest values of specificity (0.54), sensitivity (0.81) and accuracy (0.69). The Spearman rank correlation coefficients for crown/root caries with histology were 0.54/0.37 (LFpen), 0.29/0.10 (BW), 0.29/0.18 (VE) and 0.23/0.37 (VEBW). For the LFpen, the ICC varied from 0.80 (interexaminer) to 0.97 (intraexaminer B); the kappa value was 0.19 for BW and 0.35 for VE (interexaminer). Intraexaminer kappa values for BW were 0.25 (A) and 0.29 (B), and those for VE were 0.31 (A) and 0.32 (B). The LFpen device exhibited a performance comparable to that of conventional methods but with higher interexaminer reproducibility. Therefore, the LFpen should be considered an auxiliary method for the detection of secondary approximal caries associated with composite restorations.

Publication types

  • Comparative Study

MeSH terms

  • Composite Resins* / chemistry
  • Dental Caries / diagnosis*
  • Dental Caries / diagnostic imaging
  • Dental Caries / pathology
  • Dental Materials* / chemistry
  • Dental Restoration, Permanent*
  • Fluorescence
  • Hardness
  • Humans
  • Lasers* / standards
  • Observer Variation
  • Radiography, Bitewing
  • Recurrence
  • Reproducibility of Results
  • Root Caries / diagnosis
  • Root Caries / diagnostic imaging
  • Root Caries / pathology
  • Sensitivity and Specificity
  • Tooth Crown / diagnostic imaging
  • Tooth Crown / pathology
  • Tooth Root / diagnostic imaging
  • Tooth Root / pathology
  • Visual Perception / physiology

Substances

  • Composite Resins
  • Dental Materials