Evaluation of ultrasound-assisted extraction as sample pre-treatment for quantitative determination of rare earth elements in marine biological tissues by inductively coupled plasma-mass spectrometry

Anal Chim Acta. 2010 Oct 29;679(1-2):49-55. doi: 10.1016/j.aca.2010.09.004. Epub 2010 Sep 15.

Abstract

In this work, the determination of rare earth elements (REEs), i.e. Y, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu in marine biological tissues by inductively coupled-mass spectrometry (ICP-MS) after a sample preparation method based on ultrasound-assisted extraction (UAE) is described. The suitability of the extracts for ICP-MS measurements was evaluated. For that, studies were focused on the following issues: (i) use of clean up of extracts with a C18 cartridge for non-polar solid phase extraction; (ii) use of different internal standards; (iii) signal drift caused by changes in the nebulization efficiency and salt deposition on the cones during the analysis. The signal drift produced by direct introduction of biological extracts in the instrument was evaluated using a calibration verification standard for bracketing (standard-sample bracketing, SSB) and cumulative sum (CUSUM) control charts. Parameters influencing extraction such as extractant composition, mass-to-volume ratio, particle size, sonication time and sonication amplitude were optimized. Diluted single acids (HNO(3) and HCl) and mixtures (HNO(3)+HCl) were evaluated for improving the extraction efficiency. Quantitative recoveries for REEs were achieved using 5 mL of 3% (v/v) HNO(3)+2% (v/v) HCl, particle size <200 μm, 3 min of sonication time and 50% of sonication amplitude. Precision, expressed as relative standard deviation from three independent extractions, ranged from 0.1 to 8%. In general, LODs were improved by a factor of 5 in comparison with those obtained after microwave-assisted digestion (MAD). The accuracy of the method was evaluated using the CRM BCR-668 (mussel tissue). Different seafood samples of common consumption were analyzed by ICP-MS after UAE and MAD.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Analytic Sample Preparation Methods*
  • Animals
  • Environmental Monitoring / methods
  • Hydrochloric Acid
  • Limit of Detection
  • Mass Spectrometry / methods
  • Metals, Rare Earth / analysis*
  • Microwaves
  • Mytilus edulis / chemistry*
  • Nitric Acid
  • Reference Standards
  • Seafood / analysis*
  • Solid Phase Extraction / methods
  • Ultrasonics*

Substances

  • Metals, Rare Earth
  • Nitric Acid
  • Hydrochloric Acid