Abstract
Prosthetic valve thrombosis is rare; its complication by coronary embolism is even more uncommon and when present, often fatal. Here, we present a rare case of mechanical aortic valve thrombosis with coronary emboli presenting in cardiogenic shock, managed successfully using a hybrid approach of mechanical thrombectomy and intravenous fibrinolytic therapy.
MeSH terms
-
Combined Modality Therapy
-
Coronary Angiography
-
Coronary Occlusion / diagnostic imaging
-
Coronary Occlusion / etiology
-
Coronary Occlusion / therapy
-
Embolism / complications*
-
Embolism / therapy
-
Fluoroscopy
-
Heart Diseases / complications*
-
Heart Diseases / therapy
-
Heart Valve Prosthesis Implantation / adverse effects*
-
Heart Valve Prosthesis*
-
Humans
-
Male
-
Middle Aged
-
Shock, Cardiogenic / complications
-
Shock, Cardiogenic / therapy*
-
Thrombectomy / methods*
-
Thrombolytic Therapy*
-
Thrombosis / complications*
-
Thrombosis / therapy*