NanoDrop microvolume quantitation of nucleic acids

J Vis Exp. 2010 Nov 22:(45):2565. doi: 10.3791/2565.

Abstract

Biomolecular assays are continually being developed that use progressively smaller amounts of material, often precluding the use of conventional cuvette-based instruments for nucleic acid quantitation for those that can perform microvolume quantitation. The NanoDrop microvolume sample retention system (Thermo Scientific NanoDrop Products) functions by combining fiber optic technology and natural surface tension properties to capture and retain minute amounts of sample independent of traditional containment apparatus such as cuvettes or capillaries. Furthermore, the system employs shorter path lengths, which result in a broad range of nucleic acid concentration measurements, essentially eliminating the need to perform dilutions. Reducing the volume of sample required for spectroscopic analysis also facilitates the inclusion of additional quality control steps throughout many molecular workflows, increasing efficiency and ultimately leading to greater confidence in downstream results. The need for high-sensitivity fluorescent analysis of limited mass has also emerged with recent experimental advances. Using the same microvolume sample retention technology, fluorescent measurements may be performed with 2 μL of material, allowing fluorescent assays volume requirements to be significantly reduced. Such microreactions of 10 μL or less are now possible using a dedicated microvolume fluorospectrometer. Two microvolume nucleic acid quantitation protocols will be demonstrated that use integrated sample retention systems as practical alternatives to traditional cuvette-based protocols. First, a direct A260 absorbance method using a microvolume spectrophotometer is described. This is followed by a demonstration of a fluorescence-based method that enables reduced-volume fluorescence reactions with a microvolume fluorospectrometer. These novel techniques enable the assessment of nucleic acid concentrations ranging from 1 pg/ μL to 15,000 ng/ μL with minimal consumption of sample.

Publication types

  • Video-Audio Media

MeSH terms

  • Fluorescent Dyes / chemistry
  • Nanotechnology / instrumentation
  • Nanotechnology / methods*
  • Nucleic Acids / analysis*
  • Organic Chemicals / chemistry
  • Sensitivity and Specificity
  • Spectrometry, Fluorescence / instrumentation
  • Spectrometry, Fluorescence / methods*

Substances

  • Fluorescent Dyes
  • Nucleic Acids
  • Organic Chemicals
  • PicoGreen