Diagnostic performance of a modified biophysical profile for fetal acidemia in high-risk pregnancies

J Med Assoc Thai. 2004 Oct:87 Suppl 3:S12-7.

Abstract

Objective: To determine the diagnostic performance of NST, AFI and modified-BPP for screening fetal acidemia in high-risk pregnancies.

Design: Diagnostic tests.

Setting: Srinagarind (tertiary) Hospital, Faculty of Medicine, Khon Kaen University.

Material and method: Between April 2000 and August 2001, we included 185 high risk singleton pregnancies, GA > 37 weeks, with NST and AFI once a week until delivery. Immediately after delivery, the umbilical artery blood gases were evaluated. Fetal acidemia was defined as an umbilical artery pH < 7.15. An abnormal modified-BPP was identified when either the NST was non-reactive or the AFI was < or = 5 cm.

Results: Thirteen high risk pregnancies were excluded because the last test was more than 7 days before delivery. Of the remaining 172 pregnancies, total fetal acidemia was identified in 19 cases. The incidence of fetal acidemia was 11.05% (95% CI 6.63-15.73). Among the 19 cases, eight had non-reactive NST and 11 had AFI < or = 5 cm but 14 with abnormal modified-BPP. The sensitivity of NST, AFI and modified-BPP was 42.11% (95% CI 34.73-49.48), 57.89% (95% CI 50.52-65.27), and 73.68%. (95% CI 67.10-80.27), respectively. The specificity, PPV, NPV, accuracy of NST, AFI and modified-BPP were high but not statistically different.

Conclusion: The modified-BPP had a significantly higher sensitivity than NST or AFI alone in screening for fetal acidemia, so a modified-BPP should be used to screen for fetal acidemia in high-risk pregnancies.

MeSH terms

  • Amniotic Fluid / diagnostic imaging*
  • Biophysics
  • Female
  • Fetal Blood / chemistry*
  • Fetal Distress / diagnosis*
  • Fetal Monitoring / methods*
  • Gestational Age
  • Humans
  • Hydrogen-Ion Concentration
  • Infant, Newborn
  • Predictive Value of Tests
  • Pregnancy
  • Pregnancy Outcome
  • Pregnancy, High-Risk*
  • Prenatal Diagnosis
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Thailand
  • Ultrasonography, Prenatal*