Closed-loop control of mechanical ventilation: description and classification of targeting schemes
- PMID: 21235841
- DOI: 10.4187/respcare.00967
Closed-loop control of mechanical ventilation: description and classification of targeting schemes
Abstract
There has been a dramatic increase in the number and complexity of new ventilation modes over the last 30 years. The impetus for this has been the desire to improve the safety, efficiency, and synchrony of ventilator-patient interaction. Unfortunately, the proliferation of names for ventilation modes has made understanding mode capabilities problematic. New modes are generally based on increasingly sophisticated closed-loop control systems or targeting schemes. We describe the 6 basic targeting schemes used in commercially available ventilators today: set-point, dual, servo, adaptive, optimal, and intelligent. These control systems are designed to serve the 3 primary goals of mechanical ventilation: safety, comfort, and liberation. The basic operations of these schemes may be understood by clinicians without any engineering background, and they provide the basis for understanding the wide variety of ventilation modes and their relative advantages for improving patient-ventilator synchrony. Conversely, their descriptions may provide engineers with a means to better communicate to end users.
Similar articles
-
The role of ventilator graphics when setting dual-control modes.Respir Care. 2005 Feb;50(2):187-201. Respir Care. 2005. PMID: 15691391 Review.
-
Understanding mechanical ventilators.Expert Rev Respir Med. 2010 Dec;4(6):809-19. doi: 10.1586/ers.10.66. Expert Rev Respir Med. 2010. PMID: 21128755 Review.
-
Computer control of mechanical ventilation.Respir Care. 2004 May;49(5):507-17. Respir Care. 2004. PMID: 15107139
-
Patient-ventilator interactions: optimizing conventional ventilation modes.Respir Care. 2011 Jan;56(1):73-84. doi: 10.4187/respcare.00953. Respir Care. 2011. PMID: 21235840
-
A new system for understanding modes of mechanical ventilation.Respir Care. 2001 Jun;46(6):604-21. Respir Care. 2001. PMID: 11353550 Review.
Cited by
-
An audio-semantic multimodal model for automatic obstructive sleep Apnea-Hypopnea Syndrome classification via multi-feature analysis of snoring sounds.Front Neurosci. 2024 May 10;18:1336307. doi: 10.3389/fnins.2024.1336307. eCollection 2024. Front Neurosci. 2024. PMID: 38800571 Free PMC article.
-
Flow-Limited and Reverse-Triggered Ventilator Dyssynchrony Are Associated With Increased Tidal and Dynamic Transpulmonary Pressure.Crit Care Med. 2024 May 1;52(5):743-751. doi: 10.1097/CCM.0000000000006180. Epub 2024 Jan 12. Crit Care Med. 2024. PMID: 38214566
-
The Complexities of Mechanical Ventilation: Toppling the Tower of Babel.Respir Care. 2023 Jun;68(6):796-820. doi: 10.4187/respcare.10828. Respir Care. 2023. PMID: 37225651 Free PMC article.
-
The Evolution of Intermittent Mandatory Ventilation.Respir Care. 2023 Mar;68(3):417-428. doi: 10.4187/respcare.10184. Epub 2022 Oct 4. Respir Care. 2023. PMID: 36195349 Free PMC article. Review.
-
Design and simulation of AI-based low-cost mechanical ventilator: An approach.Mater Today Proc. 2021;47:5886-5891. doi: 10.1016/j.matpr.2021.04.369. Epub 2021 May 28. Mater Today Proc. 2021. PMID: 34075333 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources