Improved measurements of Na+ fluxes in plants using calixarene-based microelectrodes

J Plant Physiol. 2011 Jul 1;168(10):1045-51. doi: 10.1016/j.jplph.2010.12.006. Epub 2011 Jan 22.

Abstract

Ion-selective microelectrodes are a powerful tool in studying adaptive responses of plant cells and tissues to various abiotic stresses. However, application of this technique in Na(+) flux measurements was limited due to poor selectivity for Na(+) ions of commercially available Na(+) cocktails. Often, these cocktails cannot discriminate between Na(+) and other interfering ions such as K(+) and Ca(2+), leading to inaccurate measurements of Na(+) concentration and, consequently, inaccurate Na(+) flux calculations. To overcome this problem, three Na(+)-selective cocktail mixtures were prepared using tetramethoxyethyl ester derivative of p-t-butyl calix[4]arene. These cocktail mixtures were compared with commercially available ETH 227-based Na(+) cocktail for selectivity for Na(+) ions over other ions (particularly K(+) and Ca(2+)). Among the three calixarene-based Na(+) cocktails tested, cocktail 2 [in % w/w: Na(+) ionophore (4-tert-butylcalix[4]arene-tetra acetic acid tetraethyl ester) 3.5, the plasticizer (2-nitrophenyl octyl ether) 95.9 and lipophilic anion (potassium tetrakis (4-chlorophenyl) borate) 0.6] showed the best selectivity for Na(+) ions over K(+) and Ca(2+) ions and was highly stable over time (up to 10h). Na(+) flux measurements under a wide range of NaCl concentrations (25-150 mM) using Na(+) cocktail 2 established a clear dose-response relationship between severity of salt stress and magnitude of Na(+) influx at the distal elongation and mature zones of Arabidopsis thaliana roots. Furthermore, Na(+) cocktail 2 was compared with commercially available ETH 227-based Na(+) cocktail by measuring Na(+) fluxes at the two Arabidopsis root zones in response to 100mM NaCl treatment. With calixarene-based Na(+) cocktail 2, a large decreasing Na(+) influx (0-15 min) followed by small Na(+) influx (15-45 min) was measured, whereas with ETH-based Na(+) cocktail Na(+) influx was short-lived (1-3 min) and was followed by Na(+) efflux (3-45 min) that might have been due to K(+) and Ca(2+) efflux measured together with Na(+) influx. In conclusion, Na(+)-selective calixarene-based microelectrodes have excellent potential to be used in real-time Na(+) flux measurements in plants.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Acetamides
  • Arabidopsis / chemistry*
  • Arabidopsis / physiology
  • Calcium / analysis
  • Calcium / metabolism
  • Calibration
  • Calixarenes*
  • Ion Transport
  • Ion-Selective Electrodes*
  • Ionophores
  • Microelectrodes
  • Plant Roots / chemistry
  • Plant Roots / physiology
  • Potassium / analysis
  • Potassium / metabolism
  • Seedlings / chemistry
  • Seedlings / physiology
  • Sodium / analysis*
  • Sodium / metabolism
  • Sodium Chloride / pharmacology
  • Time Factors

Substances

  • Acetamides
  • Ionophores
  • Calixarenes
  • Sodium Chloride
  • ETH 227
  • Sodium
  • Potassium
  • Calcium