Laparoscopic versus open insertion of the peritoneal catheter in ventriculoperitoneal shunt placement: review of 810 consecutive cases
- PMID: 21314272
- DOI: 10.3171/2011.1.JNS101492
Laparoscopic versus open insertion of the peritoneal catheter in ventriculoperitoneal shunt placement: review of 810 consecutive cases
Abstract
Object: Traditional ventriculoperitoneal (VP) shunt surgery involves insertion of the distal catheter by minilaparotomy. However, minilaparotomy may be a significant source of morbidity during shunt surgery. Laparoscopic insertion of the distal catheter is an alternative technique that may simplify and improve the safety of shunt surgery.
Methods: The authors performed a retrospective review of hospital records of all patients undergoing new VP shunt insertion at a tertiary care center between 2004 and 2009. Patient characteristics and outcomes were compared between patients undergoing open or laparoscopic insertion of the distal catheter. Independent variables in the analysis included age, sex, race, body mass index, surgical technique, previous VP shunt placement, previous abdominal procedures, American Society of Anesthesiology (ASA) score, and indication for shunt placement. Dependent variables included the occurrence of shunt failure, cause of shunt failure, complications, length of stay (LOS), LOS after shunt placement, estimated blood loss, and operative time.
Results: The authors identified 810 patients who met the inclusion criteria; open or laparoscopic distal catheter insertion was performed in 335 and 475 patients, respectively. There were no significant differences between the groups regarding age, race, ASA score, or indication for shunt placement. The most common indication was hydrocephalus due to subarachnoid hemorrhage, followed by tumor-associated hydrocephalus, normal pressure hydrocephalus (NPH), and hydrocephalus due to trauma. The incidence of shunt failure was not statistically different between cohorts, occurring in 20.0% of laparoscopic and 20.9% of open catheter placement cases (p = 0.791). With analysis of causes of shunt failure, shunt obstruction occurred significantly more often in the open surgery cohort (p = 0.012). In patients with a known cause shunt obstruction, distal obstruction occurred in 35.7% of the open cohort obstructions and 4.8% of the laparoscopic cohort obstructions (p = 0.014). The relative risk of distal obstruction in open cases compared with laparoscopic cases was 7.50. Infections occurred in 8.2% of laparoscopic cases compared with 6.6% of open cases (p = 0.419). Within the NPH subgroup, the laparoscopically treated patients had significantly more overdrainage (p = 0.040), whereas those in the open cohort experienced significantly more shunt obstructions (p = 0.034). Laparoscopically treated patients had shorter operative times (p < 0.0005), inpatient LOS (p < 0.001), and inpatient LOS after VP shunt placement (p = 0.01) as well as less blood loss (p = 0.058).
Conclusions: To our knowledge this is the largest reported comparison of distal VP shunt catheter insertion techniques. Compared with minilaparotomy, the laparoscopic approach was associated with decreased time in the operating room and a decreased LOS. Moreover, laparoscopy was associated with fewer distal shunt obstructions. Laparoscopic shunt surgery is a viable alternative to traditional shunt surgery.
Similar articles
-
Open versus laparoscopic ventriculoperitoneal shunt placement in children: a systematic review and meta-analysis.Childs Nerv Syst. 2023 Jul;39(7):1895-1902. doi: 10.1007/s00381-023-05966-5. Epub 2023 May 25. Childs Nerv Syst. 2023. PMID: 37225936 Free PMC article. Review.
-
Influence of distal insertion technique, valve selection, and patient demographics on shunt survival in ventriculoperitoneal shunt insertion: A retrospective analysis of an Australian case series.J Clin Neurosci. 2024 Jul;125:168-174. doi: 10.1016/j.jocn.2024.05.021. Epub 2024 May 30. J Clin Neurosci. 2024. PMID: 38820856
-
Laparoscopic-assisted Peritoneal Shunt Insertion for Ventriculoperitoneal and Lumboperitoneal Shunt Placement: An Institutional Experience of 53 Consecutive Cases.Surg Laparosc Endosc Percutan Tech. 2015 Jun;25(3):235-7. doi: 10.1097/SLE.0000000000000141. Surg Laparosc Endosc Percutan Tech. 2015. PMID: 25738700
-
Laparoscopically assisted ventriculoperitoneal shunt placement: a prospective randomized controlled trial.J Neurosurg. 2015 May;122(5):1058-67. doi: 10.3171/2014.9.JNS132791. Epub 2014 Dec 23. J Neurosurg. 2015. PMID: 25534231 Clinical Trial.
-
Laparoscopy versus mini-laparotomy peritoneal catheter insertion of ventriculoperitoneal shunts: a systematic review and meta-analysis.Neurosurg Focus. 2016 Sep;41(3):E7. doi: 10.3171/2016.5.FOCUS1637. Neurosurg Focus. 2016. PMID: 27581319 Review.
Cited by
-
Falciform technique in laparoscopic revision of distal catheter obstruction: an evaluation.Ann Med Surg (Lond). 2024 Apr 17;86(6):3310-3314. doi: 10.1097/MS9.0000000000002066. eCollection 2024 Jun. Ann Med Surg (Lond). 2024. PMID: 38846879 Free PMC article.
-
Bilateral abducens and facial nerve palsies following fourth ventriculoperitoneal shunt with laparoscopic-assisted abdominal catheter placement.Brain Spine. 2024 Apr 22;4:102824. doi: 10.1016/j.bas.2024.102824. eCollection 2024. Brain Spine. 2024. PMID: 38706799 Free PMC article.
-
Outcomes of ventriculoperitoneal shunt placement with or without laparoscopic assistance: An analysis of the national inpatient sample.World Neurosurg X. 2023 Dec 9;21:100266. doi: 10.1016/j.wnsx.2023.100266. eCollection 2024 Jan. World Neurosurg X. 2023. PMID: 38204764 Free PMC article.
-
Two-point fixation enhanced the outcome of laparoscopy-assisted ventriculoperitoneal shunt in adult patients with hydrocephalus: a retrospective study.Front Surg. 2023 Jul 13;10:1135818. doi: 10.3389/fsurg.2023.1135818. eCollection 2023. Front Surg. 2023. PMID: 37529658 Free PMC article.
-
Open versus laparoscopic ventriculoperitoneal shunt placement in children: a systematic review and meta-analysis.Childs Nerv Syst. 2023 Jul;39(7):1895-1902. doi: 10.1007/s00381-023-05966-5. Epub 2023 May 25. Childs Nerv Syst. 2023. PMID: 37225936 Free PMC article. Review.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous