Review
. 2011 Mar;25(1):77-102.
doi: 10.1016/j.idc.2010.11.012.

Central line-associated bloodstream infections: prevention and management

Affiliations
Review

Central line-associated bloodstream infections: prevention and management

David J Weber et al. Infect Dis Clin North Am. 2011 Mar.

Abstract

Approximately 80,000 central venous line-associated bloodstream infections (CLA-BSI) occur in the United States each year. CLA-BSI is most commonly caused by coagulase-negative staphylococci, Staphylococcus aureus, Candida spp, and aerobic gram-negative bacilli. These organisms commonly gain entrance in into the bloodstream via the catheter-skin interface (insertion site) or via the catheter hub. Use of strict aseptic technique for insertion is the key method for the prevention of CLA-BSI. Various methods can be used to reduce unacceptably high rates of CLA-BSI, including use of an antiseptic- or antibiotic-impregnated catheter, daily chlorhexidine baths/washes, and placement of a chlorhexidine-impregnated sponge over the insertion site.