Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2011 Feb 25;6(2):e17056.
doi: 10.1371/journal.pone.0017056.

Image-derived input function for human brain using high resolution PET imaging with [C](R)-rolipram and [C]PBR28

Affiliations
Comparative Study

Image-derived input function for human brain using high resolution PET imaging with [C](R)-rolipram and [C]PBR28

Paolo Zanotti-Fregonara et al. PLoS One. .

Abstract

Background: The aim of this study was to test seven previously published image-input methods in state-of-the-art high resolution PET brain images. Images were obtained with a High Resolution Research Tomograph plus a resolution-recovery reconstruction algorithm using two different radioligands with different radiometabolite fractions. Three of the methods required arterial blood samples to scale the image-input, and four were blood-free methods.

Methods: All seven methods were tested on twelve scans with [(11)C](R)-rolipram, which has a low radiometabolite fraction, and on nineteen scans with [(11)C]PBR28 (high radiometabolite fraction). Logan V(T) values for both blood and image inputs were calculated using the metabolite-corrected input functions. The agreement of image-derived Logan V(T) values with the reference blood-derived Logan V(T) values was quantified using a scoring system. Using the image input methods that gave the most accurate results with Logan analysis, we also performed kinetic modelling with a two-tissue compartment model.

Results: For both radioligands the highest scores were obtained with two blood-based methods, while the blood-free methods generally performed poorly. All methods gave higher scores with [(11)C](R)-rolipram, which has a lower metabolite fraction. Compartment modeling gave less reliable results, especially for the estimation of individual rate constants.

Conclusion: OUR STUDY SHOWS THAT: 1) Image input methods that are validated for a specific tracer and a specific machine may not perform equally well in a different setting; 2) despite the use of high resolution PET images, blood samples are still necessary to obtain a reliable image input function; 3) the accuracy of image input may also vary between radioligands depending on the magnitude of the radiometabolite fraction: the higher the metabolite fraction of a given tracer (e.g., [(11)C]PBR28), the more difficult it is to obtain a reliable image-derived input function; and 4) in association with image inputs, graphical analyses should be preferred over compartmental modelling.

PubMed Disclaimer

Conflict of interest statement

Competing Interests: The authors have declared that no competing interests exist.

Figures

Figure 1
Figure 1. Transaxial slices from a [11C](R)-rolipram brain scan of a healthy volunteer and from a simulated study using a digital phantom.
Upper row: [11C](R)-rolipram images across the thalamus summed over the whole duration of the scan from a phantom (A) and a healthy volunteer (B). The phantom images are realistic and quite similar to those from the real subjects. The external rim of activity surrounding the brain, in both the subject and the phantom, is scalp activity. Middle row: images summed over the first two minutes at the carotid level. The carotids are well visible near the temporal lobes for both the phantom (C) and the healthy volunteer (D). The regions of high activity visible in the lower part of the cerebellum of the subject (D) are the cerebellar venous sinuses (not simulated in the phantom studies). Bottom row: late images (three summed frames taken at about 1 hour after injection) from a phantom (E) and a subject (F). At late times the carotids are not well visible anymore and the spill-over effect from surrounding tissues becomes more important.
Figure 2
Figure 2. The average concentrations of radioactivity in whole blood (solid line) and parent radioligand in plasma (dashed line) over time for [11C](R)-rolipram (n = 12) (A) and [11C]PBR28 (n = 19) (B).
The main figures show the first 20 minutes of the curves and the inserts the remaining part. Although the shape of the whole blood curves was similar for the two tracers, the relative concentration of parent and metabolites differed. The mean ratio of concentration of parent radioligand in plasma to total radioactivity in whole blood (C) showed that [11C](R)-rolipram remained the predominant component of whole blood radioactivity throughout the scan. In contrast, radiometabolites of [11C]PBR28 became the predominant component of whole blood radioactivity after the first few minutes.
Figure 3
Figure 3. The concentrations over time of [11C](R)-rolipram (A and B) and [11C]PBR28 (C and D) in plasma from the arterial input function (solid line) and from the image input function (dashed line) of a representative healthy subject.
The curves are representative of those from a blood-based (Chen; A and C) and a blood-free (Su; B and D). None of the methods precisely estimated the peak in all the subjects but, in general, blood-based methods yielded a better estimate of the tails of the curves.

Similar articles

Cited by

References

    1. Everett BA, Oquendo MA, Abi-Dargham A, Nobler MS, Devanand DP, et al. Safety of radial arterial catheterization in PET research subjects. J Nucl Med. 2009;50:1742. - PMC - PubMed
    1. Chen K, Bandy D, Reiman E, Huang SC, Lawson M, et al. Noninvasive quantification of the cerebral metabolic rate for glucose using positron emission tomography, 18F-fluoro-2-deoxyglucose, the Patlak method, and an image-derived input function. J Cereb Blood Flow Metab. 1998;18:716–723. - PubMed
    1. Mourik JE, Lubberink M, Klumpers UM, Comans EF, Lammertsma AA, et al. Partial volume corrected image derived input functions for dynamic PET brain studies: methodology and validation for [11C]flumazenil. Neuroimage. 2008;39:1041–1050. - PubMed
    1. Naganawa M, Kimura Y, Ishii K, Oda K, Ishiwata K, et al. Extraction of a plasma time-activity curve from dynamic brain PET images based on independent component analysis. IEEE Trans Biomed Eng. 2005;52:201–210. - PubMed
    1. Su KH, Wu LC, Liu RS, Wang SJ, Chen JC. Quantification method in [18F]fluorodeoxyglucose brain positron emission tomography using independent component analysis. Nucl Med Commun. 2005;26:995–1004. - PubMed

MeSH terms

LinkOut - more resources