Flat-detector computed tomography in the assessment of intracranial stents: comparison with multi detector CT and conventional angiography in a new animal model

Eur Radiol. 2011 Aug;21(8):1779-87. doi: 10.1007/s00330-011-2093-7. Epub 2011 Mar 2.

Abstract

Objective: Careful follow up is necessary after intracranial stenting because in-stent restenosis (ISR) or residual stenosis (RS) is not rare. A minimally invasive follow-up imaging technique is desirable. The objective was to compare the visualisation of stents in Flat Detector-CT Angiography (FD-CTA) after intravenous contrast medium injection (i.v.) with Multi Detector Computed Tomography Angiography (MD-CTA) and Digital Subtracted Angiography (DSA) in an animal model.

Methods: Stents were implanted in the carotid artery of 12 rabbits. In 6 a residual stenosis (RS) was surgically created. Imaging was performed using FD-CTA, MD-CTA and DSA. Measurements of the inner and outer diameter and cross-section area of the stents were performed. Stenosis grade was calculated.

Results: In subjective evaluation FD-CTA was superior to MD-CTA. FD-CTA was more accurate compared with DSA than MD-CTA. Cross-sectional area of the stent lumen was significantly larger (p < 0.05) in FD-CTA in comparison to MD-CTA. Accurate evaluation of stenosis was impossible in MD-CTA. There was no statistically significant difference in the stenosis grade of DSA and FD-CTA.

Conclusion: Our results show that visualisation of stent and stenosis using intravenous FD-CTA compares favourably with DSA and may replace DSA in the follow-up of patients treated with intracranial stents.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Angiography, Digital Subtraction
  • Animals
  • Cerebral Angiography / methods*
  • Contrast Media / administration & dosage
  • Image Processing, Computer-Assisted
  • Rabbits
  • Statistics, Nonparametric
  • Stents*
  • Tomography, X-Ray Computed / methods

Substances

  • Contrast Media