Derivatization and fragmentation pattern analysis of natural and synthetic steroids, as their trimethylsilyl (oxime) ether derivatives by gas chromatography mass spectrometry: analysis of dissolved steroids in wastewater samples

J Chromatogr A. 2011 Apr 8;1218(14):1878-90. doi: 10.1016/j.chroma.2011.01.051. Epub 2011 Feb 2.

Abstract

This paper reports the extension of our multiresidue analysis (MA) procedure with 18 natural and synthetic steroids; permitting the identification and quantification, in total of 81 pollutants from one solution, by a single injection, as their trimethylsilyl (TMS)-oxime ether/ester derivatives, by gas chromatography-mass spectrometry (GC-MS), within 31 min. As a novelty to the field, basic researches, such as fragmentation pattern analysis and derivatization optimization studies were performed for androsterone, transdehydroandrosterone, transandrosterone, mestranol, dihydrotestosterone, ethinylestradiol, testosterone, norethisterone, estriol, 4-androstene-3,17-dione, gestodene, levonorgestrel, etonogestrel, coprostanol, progesterone, cholesterol, medroxy-progesterone-acetate, stigmasterol and β-sitosterol. Results confirmed that (i) the TMS oxime-ether derivatives of the keto steroids provide from 1.40 times (gestodene) up to 4.25 times (norethisterone) higher responses compared to their TMS-ether ones, and (ii) the distribution of syn/anti oximes is characteristic to the ketosteroid species examined. Based on our optimized mass fragmentation, solid phase extraction (SPE) and derivatization studies separations have been performed in the total ion current (TIC) mode, identification and quantification of compounds have been carried out on the basis of their selective fragment ions. Responses, obtained with derivatized standards proved to be linear (hydroxysteroids), or have been calculated from calibration curves (ketosteroids) in the range of 1.88-750ng/L levels. Limit of quantitation (LOQ) values varied between 1.88ng/L and 37.5ng/L concentrations. The most important practical messages of this work are the high androsterone (0.744-4.28μg/L), transandrosterone (0.138-4.00μg/L), coprostanol (2.11-302μg/L), cholesterol (0.308-41μg/L), stigmasterol (1.21-8.40μg/L) and β-sitosterol (1.12-11.0μg/L) contents of influent wastewaters. β-Estradiol (100ng/L) and estriol (54ng/L) were found in one influent sample, only. Reproducibilities, characterized with the relative standard deviation percentages (RSD%) of measurements, varied between 1.73 RSD% (β-estradiol) and 5.4 RSD% (stigmasterol), with an average of 4.82 RSD%.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Ethers / chemistry
  • Gas Chromatography-Mass Spectrometry / methods*
  • Oximes / chemistry
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Sewage / chemistry
  • Solid Phase Extraction
  • Steroids / analysis
  • Steroids / chemistry*
  • Trimethylsilyl Compounds / chemistry
  • Water Pollutants, Chemical / analysis
  • Water Pollutants, Chemical / chemistry*