Superior medial geniculate artery pseudoaneurysm after primary total knee arthroplasty

J Arthroplasty. 2012 Feb;27(2):323.e13-6. doi: 10.1016/j.arth.2011.02.009. Epub 2011 Mar 23.

Abstract

Vascular complications after total knee arthroplasty are rare. To date, there are 7 reported cases of pseudoaneurysms affecting the popliteal artery and 6 cases affecting one of the geniculate arteries. We present a case of a geniculate artery pseudoaneurysm that shared symptoms of a deep venous thrombosis on physical examination of a patient who underwent primary total knee arthroplasty. To date, there are no reports in American literature of pseudoaneurysms affecting the superior medial geniculate artery after primary total knee arthroplasty. After a vascular workup including computed tomographic angiography, surgical management included evacuation of the pseudoaneurysm and ligation of the feeding artery. The patient went on to successful recovery.

Publication types

  • Case Reports

MeSH terms

  • Aged
  • Aneurysm, False / diagnostic imaging*
  • Aneurysm, False / etiology*
  • Aneurysm, False / surgery
  • Arteries*
  • Arthroplasty, Replacement, Knee / adverse effects*
  • Female
  • Humans
  • Knee Joint / blood supply*
  • Knee Joint / surgery
  • Osteoarthritis, Knee / surgery
  • Popliteal Artery
  • Tomography, X-Ray Computed
  • Treatment Outcome
  • Vascular Surgical Procedures