"K2/SPICE" products are commonly laced with aminoalkylindole synthetic cannabinoids (i.e., JWH-018 and JWH-073) and are touted as "legal" marijuana substitutes. Here we validate a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for measuring urinary concentrations of JWH-018, JWH-073, and several potential metabolites of each. The analytical procedure has high capacity for sample throughput and does not require solid phase or liquid extraction. Evaluation of human urine specimens collected after the subjects reportedly administered JWH-018 or a mixture of JWH-018 and JWH-073 provides preliminary evidence of clinical utility. Two subjects that consumed JWH-018 primarily excreted glucuronidated conjugates of 5-(3-(1-naphthoyl)-1H-indol-1-yl)-pentanoic acid (>30 ng/mL) and (1-(5-hydroxypentyl)-1H-indol-3-yl)(naphthalene-1-yl)-methanone (>50 ng/mL). Interestingly, oxidized metabolites of both JWH-018 and JWH-073 were detected in these specimens, suggesting either metabolic demethylation of JWH-018 to JWH-073 or a nonreported, previous JWH-073 exposure. Metabolic profiles generated from a subject who consumed a mixture of JWH-018 and JWH-073 were similar to profiles generated from subjects who presumably consumed JWH-018 exclusively. Oxidized metabolites of JWH-018 and JWH-073 were of the same pattern, but JWH-018 metabolites were excreted at lower concentrations. These results begin clinically validating the LC-MS/MS assay for detecting and quantifying aminoalkylindole metabolites. Full validation awaits further testing.

Figures

Figure 1
Figure 1
Structures of JWH-018 (compound 1), 5 hyroxylated metabolites of JWH-018 (compounds 2 – 6) and a carboxylated derivative of JWH-018 (Compound 7).
Figure 2
Figure 2
Structures of JWH-073 (Compound 7), 5 hyroxylated metabolites of JWH-073 (compounds 8–13) and a carboxylated derivative of JWH-073 (Compound 14).
Figure 3
Figure 3
Resulting enhanced product ion produced from compounds 1–7 (Figure 1).
Figure 4
Figure 4
Resulting enhanced product ion produced from compounds 8–14 (Figure 2).
Figure 5
Figure 5
Resulting chromatograph produced from 50 ng/mL QC standard prepared in human urine. Chromatography was similar in all standards and unknown specimens. Different color tracings are representative of Specific Reaction Monitoring experiments (Table 1) used to detect compounds 1–14 (Figures 1 – 2).
Figure 6
Figure 6
Extracted ion chromatographs from Specific Reaction Monitoring experiments performed with Specimen 1 before (black dash tracing) and after (red tracing) β-glucuronidase incubation. Signal for m/z (A) 358/155, (B) 372/155, and (C) 344/155 were used to monitor compounds 2–5 and 14; Compound 7; and compounds 9–13, respectively. This specimen was collected after JWH-018 use. “UK” denotes a potential contaminant or unidentified metabolites.
Figure 7
Figure 7
Extracted ion chromatographs from Specific Reaction Monitoring experiments performed with Specimen 3 before (black dash tracing) and after (red tracing) β-glucuronidase incubation. Signal for m/z (A) 358/155, (B) 372/155, and (C) 344/155 were used to monitor compounds 2–5 and 14; Compound 7; and compounds 9–13, respectively. This specimen was collected after JWH-018 and JWH-073 use. “UK” denotes a potential contaminant or unidentified metabolites.