Evaluation of absorbable and permanent mesh fixation devices: adhesion formation and mechanical strength

Hernia. 2011 Oct;15(5):553-8. doi: 10.1007/s10029-011-0826-9. Epub 2011 May 19.

Abstract

Purpose: Laparoscopic ventral hernia repair is commonly performed with mesh prostheses; however, there is no standard for fixation devices used to secure mesh to the abdominal wall. This study is a functional comparison of novel, screw-type absorbable and permanent fixation devices with a traditional titanium fixation device.

Methods: Fifteen pigs each underwent the laparoscopic placement of two 11 × 14-cm mesh prostheses and were randomized for mesh fixation with either titanium spiral tacks (TS), absorbable screw-type fasteners (SF), or permanent screw-type fasteners (PF) (n = 10 mesh prostheses for each fixation group). Adhesions were assessed laparoscopically at 4 weeks. The fixation devices were also embedded in porcine abdominal rectus muscle for ex vivo mechanical testing along with partial thickness polypropylene suture (PR) as a control group (n = 40 for each group). Maximum pull-off forces were measured. All statistical tests were two-tailed, and a P-value < 0.05 was considered to be significant.

Results: The mean tenacity adhesion scores were 1.40 ± 0.52 (PF), 1.7 ± 0.82 (SF), and 2.6 ± 1.07 (TS). Adhesions in the PF group were significantly less tenacious compared with the TS group (P = 0.01). Quantitative adhesion scores were not significantly different among groups. The maximum pull-off forces, measured in Newtons, were 28.61 N ± 4.89 N (TS), 22.71 N ± 7.86 N (SF), 16.98 N ± 7.59 N (PF), and 20.83 N ± 6.25 N (PR). The pull-off force in the TS group was higher than all of the other groups (P < 0.001). The SF group also had a higher pull-off force compared with the PF group (P < 0.001).

Conclusions: The screw-type absorbable and permanent fixation devices provided adequate fixation and were associated with decreased adhesions in this porcine model.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Analysis of Variance
  • Animals
  • Equipment Design
  • Female
  • Hernia, Ventral / surgery
  • Herniorrhaphy / instrumentation
  • Laparoscopy
  • Materials Testing
  • Prosthesis Retention / instrumentation*
  • Surgical Mesh*
  • Swine
  • Tissue Adhesions / etiology*