Complement (C1q) fixing solid-phase screening for HLA antibodies increases the availability of compatible platelet components for refractory patients
- PMID: 21615749
- DOI: 10.1111/j.1537-2995.2011.03194.x
Complement (C1q) fixing solid-phase screening for HLA antibodies increases the availability of compatible platelet components for refractory patients
Abstract
Background: Immune refractoriness to platelet (PLT) transfusion is primarily due to HLA antibody. Patients at our institution are identified as refractory due to HLA by a Luminex-based immunoglobulin (Ig)G-single-antigen-bead (SAB) assay, but in highly sensitized patients, antigen-negative compatible donors cannot be found due to the high sensitivity of the IgG-SAB method. We developed an assay that detects only HLA antibodies binding the first complement component (C1q). We hypothesized that the C1q-SAB method might be more relevant than the IgG-SAB method because the antibodies identified may activate the complement cascade causing PLT destruction.
Study design and methods: Thirteen highly sensitized refractory patients received 177 PLT units incompatible by the IgG-SAB method. They were retrospectively retested by the C1q-SAB method. Calculated percent reactive antibody (CPRA) and HLA antibody specificities were compared between the two methods and corrected count increment (CCI) values were analyzed. Additionally the impact of ABO compatibility on CCI responses was evaluated.
Results: The mean CPRA value was significantly lower by C1q-SAB (60%) than by IgG-SAB (94%; p < 0.05). Patients showed significantly better CCI (10.6 × 10(9) ± 0.8 × 10(9) /L) with C1q-compatible (n = 134) than with C1q-incompatible PLTs (n = 43) (2.5 × 10(9) ± 0.9 × 10(9) /L/m(2) ; p < 0.0001). ABO compatibility did not significantly impact the CCI values (p < 0.0001). Our results show that 75% of PLT units previously considered incompatible were actually compatible.
Conclusion: For highly refractory patients to PLT transfusion, the C1q-based SAB binding assay may be a better method for identifying clinically relevant HLA antibodies and selecting PLT units that will result in acceptable CCI.
© 2011 American Association of Blood Banks.
Similar articles
-
C1q-fixing human leukocyte antigen assay in immunized renal patients: correlation between Luminex SAB-C1q and SAB-IgG.Transplant Proc. 2012 Nov;44(9):2535-7. doi: 10.1016/j.transproceed.2012.09.084. Transplant Proc. 2012. PMID: 23146446
-
Novel C1q assay reveals a clinically relevant subset of human leukocyte antigen antibodies independent of immunoglobulin G strength on single antigen beads.Hum Immunol. 2011 Oct;72(10):849-58. doi: 10.1016/j.humimm.2011.07.001. Epub 2011 Jul 18. Hum Immunol. 2011. PMID: 21791230
-
Technical Limitations of the C1q Single-Antigen Bead Assay to Detect Complement Binding HLA-Specific Antibodies.Transplantation. 2017 Jun;101(6):1206-1214. doi: 10.1097/TP.0000000000001270. Transplantation. 2017. PMID: 27306532 Free PMC article.
-
Methods for the selection of platelet products for alloimmune-refractory patients.Transfusion. 2015 Feb;55(2):235-44. doi: 10.1111/trf.12921. Epub 2014 Nov 13. Transfusion. 2015. PMID: 25393955 Review.
-
[Platelet allo-antibodies identification strategies for preventing and managing platelet refractoriness].Transfus Clin Biol. 2014 Nov;21(4-5):193-206. doi: 10.1016/j.tracli.2014.08.140. Epub 2014 Sep 30. Transfus Clin Biol. 2014. PMID: 25277423 Review. French.
Cited by
-
Altered Fc glycosylation of anti-HLA alloantibodies in hemato-oncological patients receiving platelet transfusions.J Thromb Haemost. 2022 Dec;20(12):3011-3025. doi: 10.1111/jth.15898. Epub 2022 Oct 11. J Thromb Haemost. 2022. PMID: 36165642 Free PMC article.
-
Current Status of and Global Trends in Platelet Transfusion Refractoriness From 2004 to 2021: A Bibliometric Analysis.Front Med (Lausanne). 2022 May 6;9:873500. doi: 10.3389/fmed.2022.873500. eCollection 2022. Front Med (Lausanne). 2022. PMID: 35602482 Free PMC article.
-
Fc galactosylation of anti-platelet human IgG1 alloantibodies enhances complement activation on platelets.Haematologica. 2022 Oct 1;107(10):2432-2444. doi: 10.3324/haematol.2021.280493. Haematologica. 2022. PMID: 35354253 Free PMC article.
-
Human Leucocyte Antigen Sensitisation and Its Impact on Transfusion Practice.Transfus Med Hemother. 2019 Oct;46(5):356-369. doi: 10.1159/000502158. Epub 2019 Aug 29. Transfus Med Hemother. 2019. PMID: 31832061 Free PMC article. Review.
-
Multiplexed Fc array for evaluation of antigen-specific antibody effector profiles.J Immunol Methods. 2017 Apr;443:33-44. doi: 10.1016/j.jim.2017.01.010. Epub 2017 Feb 3. J Immunol Methods. 2017. PMID: 28163018 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials
