Assessment of pituitary adenoma volumetric change using longitudinal MR image registration

Neuroradiology. 2012 May;54(5):435-43. doi: 10.1007/s00234-011-0894-7. Epub 2011 Jun 7.

Abstract

Introduction: Change detection is a crucial factor in monitoring of slowly evolving pathologies. The objective of the study was to test a semi-automatic method applied on longitudinal MRI monitoring of volume change in pituitary macroadenomas.

Methods: The proposed method is based on a visual comparison of geometrically corrected, co-registered, intensity-normalized contrast-enhanced (CE) 3D GRE T1-weighted images. Qualitative volume changes based on this applied method were compared with experts' readings of conventional pre- and post-CE 2D T1-weighted images. Magnetic resonance (MR) imaging was performed two to four times in 13 patients with a total combination of 29 time points.

Results: Compared to conventional 2D MR readings, a diagnosis of tumor growth (yes/no) was changed in 5 of 13 patients (38%) at 9 of the 29 combinations of time points (31%) using the 3D-based semi-automatic method. With manual tumor tracings as reference, McNemar's test showed a significant difference between the two methods.

Conclusion: Visual comparison of geometrically corrected, intensity-normalized, and affine-aligned longitudinal 3D images may enable more accurate assessment of qualitative volumetric change in pituitary adenomas than conventional reading of 2D images.

Publication types

  • Comparative Study

MeSH terms

  • Adenoma / pathology*
  • Adult
  • Aged
  • Area Under Curve
  • Contrast Media
  • Female
  • Humans
  • Image Interpretation, Computer-Assisted
  • Imaging, Three-Dimensional
  • Longitudinal Studies
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Pituitary Neoplasms / pathology*
  • Prospective Studies
  • ROC Curve
  • Sensitivity and Specificity
  • Statistics, Nonparametric

Substances

  • Contrast Media