Dynamic hyperinflation and auto-positive end-expiratory pressure: lessons learned over 30 years
- PMID: 21700908
- DOI: 10.1164/rccm.201102-0226PP
Dynamic hyperinflation and auto-positive end-expiratory pressure: lessons learned over 30 years
Abstract
Auto-positive end-expiratory pressure (auto-PEEP; AP) and dynamic hyperinflation (DH) may affect hemodynamics, predispose to barotrauma, increase work of breathing, cause dyspnea, disrupt patient-ventilator synchrony, confuse monitoring of hemodynamics and respiratory system mechanics, and interfere with the effectiveness of pressure-regulated ventilation. Although basic knowledge regarding the clinical physiology and management of AP during mechanical ventilation has evolved impressively over the 30 years since DH and AP were first brought to clinical attention, novel and clinically relevant characteristics of this complex phenomenon continue to be described. This discussion reviews some of the more important aspects of AP that bear on the care of the ventilated patient with critical illness.
Similar articles
-
Measurement of air trapping, intrinsic positive end-expiratory pressure, and dynamic hyperinflation in mechanically ventilated patients.Respir Care. 2005 Jan;50(1):110-23; discussion 123-4. Respir Care. 2005. PMID: 15636649 Review.
-
Hyperinflation and intrinsic positive end-expiratory pressure: less room to breathe.Respiration. 2009;77(3):344-50. doi: 10.1159/000192790. Epub 2009 Jan 10. Respiration. 2009. PMID: 19141987 Review.
-
Hemodynamic responses to external counterbalancing of auto-positive end-expiratory pressure in mechanically ventilated patients with chronic obstructive pulmonary disease.Crit Care Med. 1994 Nov;22(11):1782-91. Crit Care Med. 1994. PMID: 7956282
-
Auto-PEEP in respiratory failure.Minerva Anestesiol. 2012 Feb;78(2):201-21. Epub 2011 Nov 18. Minerva Anestesiol. 2012. PMID: 21971439 Review.
-
Effect of different cycling-off criteria and positive end-expiratory pressure during pressure support ventilation in patients with chronic obstructive pulmonary disease.Crit Care Med. 2007 Nov;35(11):2547-52. doi: 10.1097/01.CCM.0000287594.80110.34. Crit Care Med. 2007. PMID: 17893630
Cited by
-
A self-regulated expiratory flow device for mechanical ventilation: a bench study.Intensive Care Med Exp. 2024 Oct 16;12(1):92. doi: 10.1186/s40635-024-00681-0. Intensive Care Med Exp. 2024. PMID: 39414708 Free PMC article.
-
The ventilator of the future: key principles and unmet needs.Crit Care. 2024 Aug 29;28(1):284. doi: 10.1186/s13054-024-05060-5. Crit Care. 2024. PMID: 39210377 Free PMC article. Review.
-
Heart-Lungs interactions: the basics and clinical implications.Ann Intensive Care. 2024 Aug 12;14(1):122. doi: 10.1186/s13613-024-01356-5. Ann Intensive Care. 2024. PMID: 39133379 Free PMC article. Review.
-
Modelling lung diffusion-perfusion limitation in mechanically ventilated SARS-CoV-2 patients.Front Physiol. 2024 Jul 12;15:1408531. doi: 10.3389/fphys.2024.1408531. eCollection 2024. Front Physiol. 2024. PMID: 39072215 Free PMC article.
-
Early and late effects of volatile sedation with sevoflurane on respiratory mechanics of critically ill COPD patients.Ann Intensive Care. 2024 Jun 18;14(1):91. doi: 10.1186/s13613-024-01311-4. Ann Intensive Care. 2024. PMID: 38888818 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical