Accuracy of palpating the long head of the biceps tendon: an ultrasonographic study

PM R. 2011 Nov;3(11):1035-40. doi: 10.1016/j.pmrj.2011.02.022. Epub 2011 Jun 25.

Abstract

Objective: To determine the accuracy of palpating the long head of the biceps tendon (LHBT) within the intertubercular groove with the use of ultrasonographic localization as a gold standard.

Design: Prospective, single-blinded pilot study.

Setting: Sports medicine clinic at a tertiary care academic institution.

Participants: Twenty-five male and female asymptomatic volunteers ages 24-41 years (mean, 30.9 ± 4.3 years) with body mass indices of 19.3 to 36.3 kg/m(2) (23.84 ± 4.8 kg/m(2)).

Methods: Three examiners of differing experience (a sports medicine board-certified staff physician, a sports medicine fellow, and a physical medicine and rehabilitation resident) identified the LHBT location in the intertubercular groove via palpation on a subject in the supine position and marked its location by taping an 18-gauge Tuohy needle to the skin overlying the groove. The examiner order was randomized. A fourth examiner who was blinded to the palpation order assessed the previous examiner's palpation accuracy by comparing the needle position to the sonographically determined tendon position.

Main outcome measures: Needle placement in relation to the intertubercular groove was graded as being within the groove, medial to the groove, or lateral to the groove. In the latter 2 cases, the distance from the needle to the closest groove edge was recorded.

Results: Overall accuracy rate was 5.3% (4/75), ranging from 0% (0/25) for the resident to 12% (3/25) for the fellow (P ≤ .007 for interexaminer differences). All missed palpations were localized medial to the intertubercular groove by an average of 1.4 ± 0.5 cm (range, 0.3 for the fellow to 3.5 cm for the resident).

Conclusion: Based on the current methodology, clinicians have a tendency to localize the intertubercular groove medial to its actual location. Consequently, clinicians should exercise caution when relying on clinical palpation to either diagnose a biceps tendon disorder or perform a bicipital tendon sheath injection. When clinically indicated, sonographic guidance can be used to accurately identify the LBHT within the intertubercular groove.

Publication types

  • Comparative Study
  • Randomized Controlled Trial

MeSH terms

  • Adult
  • Diagnosis, Differential
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Muscle, Skeletal*
  • Palpation / standards*
  • Pilot Projects
  • Prospective Studies
  • Reproducibility of Results
  • Shoulder*
  • Single-Blind Method
  • Tendinopathy / diagnosis*
  • Tendons / diagnostic imaging*
  • Ultrasonography
  • Young Adult