Aims to compare the efficacy of Proseal laryngeal mask airway(PLMA) and endotracheal tube (ETT) in patients undergoing laparoscopic surgeries under general anaesthesia. This prospective randomised study was conducted on 60 adult patients, 30 each in two groups, of ASA I-II who were posted for laparoscopic procedures under general anaesthesia. After preoxygenation, anaesthesia was induced with propofol, fentanyl and vecuronium. PLMA or ETT was inserted and cuff inflated. Nasogastric tube (NGT) was passed in all patients. Anaesthesia was maintained with N(2) O, O(2), halothane and vecuronium. Ventilation was set at 8 ml/kg and respiratory rate of 12/min. The attempts and time taken for insertion of devices, haemodynamic changes, oxygenation, ventilation and intraoperative and postoperative laryngopharyngeal morbidity (LPM) were noted. There was no failed insertion of devices. Time taken for successful passage of NGT was 9.77 s (6-16 s) and 11.5 s (8-17 s) for groups P and E, respectively. There were no statistically significant differences in oxygen saturation (SpO(2)) or end-tidal carbon dioxide (EtCO(2)) between the two groups before or during peritoneal insufflation. Median (range) airway pressure at which oropharyngeal leak occurred during the leak test with PLMA was 35 (24-40) cm of H(2)O. There was no case of inadequate ventilation, regurgitation, or aspiration recorded. No significant difference in laryngopharyngeal morbidity was noted. A properly positionedPLMA proved to be a suitable and safe alternative to ETT for airway management in elective fasted, adult patients undergoing laparoscopic surgeries. It provided equally effective pulmonary ventilation despite high airway pressures without gastric distention, regurgitation, and aspiration.
Keywords: Endotracheal tube; IPPV; Proseal LMA; laparoscopy; oropharyngeal seal pressure.