Iatrogenic contamination of multidose vials in simulated use. A reassessment of current patient injection technique
- PMID: 2173497
Iatrogenic contamination of multidose vials in simulated use. A reassessment of current patient injection technique
Abstract
An investigation of the potential spread of iatrogenic infections through contaminated multidose vials was performed. Contamination of a multidose vial was hypothesized to occur after a single syringe is used to inject an infected patient with medication, and the same syringe subsequently is used to withdraw additional medication from the multidose vial. If the contaminated multidose vial is used for another patient, an iatrogenic infection may be spread. Laboratory study of this injection technique found that viral plaque-forming units could be transmitted to a multidose vial in this manner. A survey of 100 fellows of the American Academy of Dermatology from the United States found that 24% of the respondents used this potentially unsafe procedure. The potential for iatrogenic spread of the human immunodeficiency virus and hepatitis B virus is described. Recommendations to avoid patient infection are made.
Similar articles
-
Multidose vial contamination in anesthesia.AANA J. 1990 Dec;58(6):462-6. AANA J. 1990. PMID: 2275319
-
Transmission of hepatitis B and C viruses in outpatient settings--New York, Oklahoma, and Nebraska, 2000-2002.MMWR Morb Mortal Wkly Rep. 2003 Sep 26;52(38):901-6. MMWR Morb Mortal Wkly Rep. 2003. PMID: 14508437
-
Model-based estimates of risks of disease transmission and economic costs of seven injection devices in sub-Saharan Africa.Bull World Health Organ. 2002;80(11):859-70. Epub 2002 Dec 3. Bull World Health Organ. 2002. PMID: 12481207 Free PMC article.
-
Unsafe injections in the developing world and transmission of bloodborne pathogens: a review.Bull World Health Organ. 1999;77(10):789-800. Bull World Health Organ. 1999. PMID: 10593026 Free PMC article. Review.
-
Best infection control practices for intradermal, subcutaneous, and intramuscular needle injections.Bull World Health Organ. 2003;81(7):491-500. Epub 2003 Sep 3. Bull World Health Organ. 2003. PMID: 12973641 Free PMC article. Review.
Cited by
-
Sterility and Stability of Diluted Carprofen in a Multidose Vial in the Laboratory Animal Setting.J Am Assoc Lab Anim Sci. 2017 May 1;56(3):296-298. J Am Assoc Lab Anim Sci. 2017. PMID: 28535864 Free PMC article.
-
Bacterial contamination of single- and multiple-dose vials after multiple use and intravenous admixtures in three different hospitals in iran.Iran J Pharm Res. 2013 Winter;12(1):205-9. Iran J Pharm Res. 2013. PMID: 24250590 Free PMC article.
-
Estimating the Burden of Disease from Unsafe Injections in India: A Cost-benefit Assessment of the Auto-disable Syringe in a Country with Low Blood-borne Virus Prevalence.Indian J Community Med. 2012 Apr;37(2):89-94. doi: 10.4103/0970-0218.96093. Indian J Community Med. 2012. PMID: 22654281 Free PMC article.
-
2007 Guideline for Isolation Precautions: Preventing Transmission of Infectious Agents in Health Care Settings.Am J Infect Control. 2007 Dec;35(10 Suppl 2):S65-164. doi: 10.1016/j.ajic.2007.10.007. Am J Infect Control. 2007. PMID: 18068815 Free PMC article. No abstract available.
-
Bacterial contamination of solutions for parenteral administration for single- and multiple-dose vials after multiple use in the hospital.Wien Med Wochenschr. 2007;157(15-16):398-401. doi: 10.1007/s10354-007-0423-9. Wien Med Wochenschr. 2007. PMID: 17922089
MeSH terms
Substances
LinkOut - more resources
Full Text Sources