Periodic spirometry in occupational setting: improving quality, accuracy, and precision

J Occup Environ Med. 2011 Oct;53(10):1205-9. doi: 10.1097/JOM.0b013e31823078b8.

Abstract

Objective: Effectiveness of periodic spirometry in medical monitoring depends on spirometry quality. We describe an intervention on spirometry quality and its impact on accuracy and precision of longitudinal measurements.

Methods: The intervention was conducted from 2005 to 2010 in a monitoring program involving approximately 2500 firefighters. Intervention supported adherence to 2005 American Thoracic Society/European Respiratory Society recommendations through monitoring of spirometry quality and longitudinal data precision, technician training, change of spirometer, and quality control.

Results: The percentage of forced vital capacity tests meeting the American Thoracic Society/European Respiratory Society criteria increased from 60% to 95% and the mean longitudinal forced expiratory volume in 1 second within-person variation decreased from 6% to 4%. The increased accuracy and precision of measurements and estimated rates of forced expiratory volume in 1 second decline were statistically significant.

Conclusion: Monitoring of quality and data precision helped to recognize the need for intervention. The intervention improved accuracy and precision of spirometry measurements and their usefulness.

Publication types

  • Research Support, U.S. Gov't, P.H.S.

MeSH terms

  • Adult
  • Forced Expiratory Volume*
  • Humans
  • Linear Models
  • Longitudinal Studies
  • Lung Diseases / diagnosis*
  • Lung Diseases / physiopathology
  • Occupational Diseases / diagnosis*
  • Occupational Diseases / physiopathology
  • Occupational Health Services / standards
  • Population Surveillance*
  • Program Evaluation
  • Quality Control
  • Quality Improvement*
  • Spirometry / standards*