Bench to bedside: dynamic mitral valve assessment

J Cardiothorac Vasc Anesth. 2011 Oct;25(5):863-6. doi: 10.1053/j.jvca.2011.06.021.

Abstract

Purpose: The authors analyze a commercially available software package capable of geometrically reconstructing the mitral valve (MV) dynamically throughout systole.

Description: Three-dimensional echocardiography has revolutionized the understanding of MV geometry. Advanced quantification software can be used to assess geometric changes in the MV, which have been shown to have important implications for MV surgery.

Evaluation: The authors performed geometric analysis on 24 patients, with both anatomically normal and abnormal MVs to assess the feasibility of this new software. The application of this new software is briefly reviewed.

Conclusion: This new software, despite its limitations, allows an improved perspective on MV geometry with implications for MV repair and surgical decision making.

MeSH terms

  • Cardiac Surgical Procedures
  • Computer Simulation
  • Echocardiography, Three-Dimensional / instrumentation*
  • Echocardiography, Three-Dimensional / methods*
  • Humans
  • Image Processing, Computer-Assisted
  • Mitral Valve / diagnostic imaging*
  • Mitral Valve / surgery
  • Mitral Valve Insufficiency / diagnostic imaging*
  • Point-of-Care Systems
  • Software
  • Systole / physiology
  • User-Computer Interface