Temperature measurement
- PMID: 21988157
- DOI: 10.1515/BMT.2011.108
Temperature measurement
Abstract
For many decades the measurement of body core temperature has been ubiquitously established in medical and non-medical applications, e.g., in hospitals, occupational medicine, sports medicine, military and other settings. However, there are still numerous challenges, such as the precise definition of the body core temperature, establishing the clinical importance of the measured temperature and the lack of a reliable, non-invasive and fast measurement method for body core temperature. After an introduction to the topic, the medical aspects from a user point of view are presented, i.e., the needs for temperature measurements, as well as possible measurement sites and clinical specifications and needs are highlighted. Subsequently, technical methods are presented which are used for temperature measurement. The analysis of the technical methods is divided into two sections: the first deals with the standard methods, which are currently used and the second describes methods, which are currently under development. Although temperature measurement appears very easy and is very common in daily use, it has many constraints, which are considered later. The need for further research is deduced from the above-mentioned sections and is finally followed by the conclusions section.
Similar articles
-
Reliability of an infrared forehead skin thermometer for core temperature measurements.J Med Eng Technol. 2006 Jul-Aug;30(4):252-61. doi: 10.1080/03091900600711381. J Med Eng Technol. 2006. PMID: 16864237 Clinical Trial.
-
Infrared ear thermometers--parameters influencing their reading and accuracy.Physiol Meas. 2005 Dec;26(6):1075-84. doi: 10.1088/0967-3334/26/6/016. Epub 2005 Nov 7. Physiol Meas. 2005. PMID: 16311454
-
A biocompatible microdevice for core body temperature monitoring in the early diagnosis of infectious disease.Biomed Microdevices. 2007 Feb;9(1):51-60. doi: 10.1007/s10544-006-9007-5. Biomed Microdevices. 2007. PMID: 17106641
-
Monitoring temperature.Nurs Times. 2005 May 17-23;101(20):30-1. Nurs Times. 2005. PMID: 15918457 Review. No abstract available.
-
Accuracy of noninvasive core temperature measurement in acutely ill adults: the state of the science.Biol Res Nurs. 2006 Jul;8(1):24-34. doi: 10.1177/1099800406289151. Biol Res Nurs. 2006. PMID: 16766626 Review.
Cited by
-
Accuracy of a zero-heat-flux thermometer in cardiac surgery, a prospective, multicentre, method comparison study.Sci Rep. 2024 Feb 7;14(1):3169. doi: 10.1038/s41598-024-53647-3. Sci Rep. 2024. PMID: 38326589 Free PMC article.
-
Thermoregulation during Field Exercise in Horses Using Skin Temperature Monitoring.Animals (Basel). 2023 Dec 30;14(1):136. doi: 10.3390/ani14010136. Animals (Basel). 2023. PMID: 38200867 Free PMC article.
-
Agreement of zero-heat-flux thermometry with the oesophageal and tympanic core temperature measurement in patient receiving major surgery.J Clin Monit Comput. 2024 Feb;38(1):197-203. doi: 10.1007/s10877-023-01078-2. Epub 2023 Oct 4. J Clin Monit Comput. 2024. PMID: 37792140 Free PMC article.
-
Accuracy of non-invasive sensors measuring core body temperature in cardiac surgery ICU patients - results from a monocentric prospective observational study.J Clin Monit Comput. 2023 Dec;37(6):1619-1626. doi: 10.1007/s10877-023-01049-7. Epub 2023 Jul 12. J Clin Monit Comput. 2023. PMID: 37436599 Free PMC article.
-
Early detection of cold stress to prevent hypothermia: A narrative review.SAGE Open Med. 2023 May 13;11:20503121231172866. doi: 10.1177/20503121231172866. eCollection 2023. SAGE Open Med. 2023. PMID: 37197020 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources