Acoustic radiation force impulse-imaging in the assessment of liver fibrosis in children

Pediatr Radiol. 2012 Feb;42(2):201-4. doi: 10.1007/s00247-011-2257-2. Epub 2011 Oct 15.

Abstract

Background: Acoustic radiation force impulse-imaging (ARFI) uses sound waves to interrogate the mechanical stiffness of a tissue.

Objective: To determine the usefulness of ARFI for estimating liver fibrosis in children.

Materials and methods: A prospective masked study of children with chronic liver disease (CLD) and/or before liver transplant (LT) comparing ARFI with histopathological analysis. Children with no history of liver disease served as a control group. ARFI was performed with Virtual Touch software using ACUSON S2000. Share wave velocities (SWV) of several regions within the liver were measured.

Results: Fifty-two children were studied (mean age 8 years; range 1-16 years). The abnormal group included 10 children (31%) with CLD and 22 (69%) planned for LT. There were 20 normal controls. Mean SWV was 1.42 m/s in the abnormal group and 1.11 m/s [corrected] in the controls. For diagnosis of fibrosis stage ≥ F1, ≥F2 and F4, the areas under the receiver-operator characteristics curves were 0.834, 0.818 and 0.983, respectively.

Conclusion: SWV is related to the degree of liver fibrosis in children, and may be a non-invasive alternative to biopsy.

MeSH terms

  • Adolescent
  • Case-Control Studies
  • Child
  • Child, Preschool
  • Elasticity Imaging Techniques / methods*
  • Female
  • Humans
  • Infant
  • Liver Cirrhosis / diagnostic imaging*
  • Male
  • Prospective Studies
  • ROC Curve
  • Software
  • Statistics, Nonparametric