Correction of misfit in a maxillary immediate metal-resin implant-fixed complete prosthesis placed with flapless surgery on four implants

Int J Oral Maxillofac Implants. 2011 Sep-Oct;26(5):e23-8.

Abstract

Immediate placement of a definitive metal-resin implant-fixed complete prosthesis on four implants after flapless computed tomographic (CT)-guided surgery was compromised because of misfit due to a discrepancy in the position of an implant. However, the definitive prosthesis could be delivered on the day of surgery with the help of laser-welding procedures. Immediate loading of four maxillary implants with a definitive prosthesis might be a viable option using the laser-welding technique in case of misfit of the prosthesis.

Publication types

  • Case Reports

MeSH terms

  • Acrylic Resins / chemistry
  • Computer-Aided Design
  • Dental Alloys / chemistry
  • Dental Implantation, Endosseous / methods*
  • Dental Implants
  • Dental Marginal Adaptation*
  • Dental Materials / chemistry
  • Dental Prosthesis, Implant-Supported*
  • Dental Soldering / instrumentation
  • Dental Soldering / methods
  • Denture Design
  • Denture, Complete, Immediate*
  • Denture, Complete, Upper*
  • Follow-Up Studies
  • Humans
  • Immediate Dental Implant Loading*
  • Jaw Relation Record
  • Lasers
  • Male
  • Middle Aged
  • Surgery, Computer-Assisted

Substances

  • Acrylic Resins
  • Dental Alloys
  • Dental Implants
  • Dental Materials