Description of Pantera Lux paclitaxel-releasing balloon and preliminary quantitative coronary angiography (QCA) results at six months in patients with coronary in-stent restenosis

EuroIntervention. 2011 May:7 Suppl K:K119-24. doi: 10.4244/EIJV7SKA20.

Abstract

Aims: Drug-eluting balloons (DEB) have recently emerged as a valuable treatment option for patients with coronary in-stent restenosis (ISR). However, little information exists on results of DEB therapy of in-stent restenosis from drug-eluting stents (DES).

Methods and results: The Pantera Lux balloon catheter, a novel DEB releasing paclitaxel with a BTHC matrix was studied in a prospective, multicentre first-in-man trial of patients with ISR either from bare metal stents (BMS) or drug-eluting stents (DES). Here we report on the clinical and angiographic follow-up of the first 45 Pantera Lux patients after six months. The mean age (± SD) of the studied ISR patients was 69 ± 9 years (82% males, 18% females). The distribution of BMS and DES in these patients was 53% and 47%, respectively. Success of deployment of the device was 100%. After six months, the major adverse cardiac event (MACE) rate was 7.7% including one post-procedural non-fatal myocardial infarction, one target lesion- and one target vessel- revascularisation (each clinically driven). Angiographic in-stent late lumen loss was 0.03 ± 0.35 mm (BMS: -0.08 ± 0.37 mm, DES: 0.15 ± 0.28 mm) as assessed by an independent angiographic core laboratory.

Conclusion: Treatment of coronary in-stent restenosis with the Pantera Lux paclitaxel-releasing balloon catheter shows very promising preliminary 6-month results, irrespective of whether the initially implanted stent was a bare metal- or a drug-eluting stent.

Publication types

  • Clinical Trial
  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Angioplasty, Balloon, Coronary / adverse effects
  • Angioplasty, Balloon, Coronary / instrumentation*
  • Cardiovascular Agents / administration & dosage*
  • Coated Materials, Biocompatible*
  • Coronary Angiography*
  • Coronary Restenosis / diagnostic imaging
  • Coronary Restenosis / therapy*
  • Drug Delivery Systems / instrumentation*
  • Drug-Eluting Stents
  • Equipment Design
  • Female
  • Germany
  • Humans
  • Male
  • Metals
  • Middle Aged
  • Myocardial Infarction / diagnostic imaging
  • Myocardial Infarction / etiology
  • Paclitaxel / administration & dosage*
  • Predictive Value of Tests
  • Prospective Studies
  • Prosthesis Design
  • Stents*
  • Time Factors
  • Treatment Outcome