Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Apr;19(4):389-94.
doi: 10.1016/j.acra.2011.12.002. Epub 2012 Jan 4.

Measurement of focal ground-glass opacity diameters on CT images: interobserver agreement in regard to identifying increases in the size of ground-glass opacities

Affiliations

Measurement of focal ground-glass opacity diameters on CT images: interobserver agreement in regard to identifying increases in the size of ground-glass opacities

Ryutaro Kakinuma et al. Acad Radiol. 2012 Apr.

Abstract

Purpose: To evaluate interobserver agreement in regard to measurements of focal ground-glass opacities (GGO) diameters on computed tomography (CT) images to identify increases in the size of GGOs.

Materials and methods: Approval by the institutional review board and informed consent by the patients were obtained. Ten GGOs (mean size, 10.4 mm; range, 6.5-15 mm), one each in 10 patients (mean age, 65.9 years; range, 58-78 years), were used to make the diameter measurements. Eleven radiologists independently measured the diameters of the GGOs on a total of 40 thin-section CT images (the first [n = 10], the second [n = 10], and the third [n = 10] follow-up CT examinations and remeasurement of the first [n = 10] follow-up CT examinations) without comparing time-lapse CT images. Interobserver agreement was assessed by means of Bland-Altman plots.

Results: The smallest range of the 95% limits of interobserver agreement between the members of the 55 pairs of the 11 radiologists in regard to maximal diameter was -1.14 to 1.72 mm, and the largest range was -7.7 to 1.7 mm. The mean value of the lower limit of the 95% limits of agreement was -3.1 ± 1.4 mm, and the mean value of their upper limit was 2.5 ± 1.1 mm.

Conclusion: When measurements are made by any two radiologists, an increase in the length of the maximal diameter of more than 1.72 mm would be necessary in order to be able to state that the maximal diameter of a particular GGO had actually increased.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources