A fully implantable stimulator with wireless power and data transmission for experimental use in epidural spinal cord stimulation
- PMID: 22256007
- DOI: 10.1109/IEMBS.2011.6091827
A fully implantable stimulator with wireless power and data transmission for experimental use in epidural spinal cord stimulation
Abstract
Epidural spinal cord stimulation (ESCS) combined with partial weight bearing therapy (PWBT) has been reported to facilitate recovery of functional walking for individuals after chronic incomplete spinal cord injury. This paper describes a low cost, fully implantable, advanced ESCS stimulator that can be manufactured in a research laboratory for use in small animals. The system is composed of four main parts: an external personal digital assistant (PDA), an external controller, an implantable pulse generator (IPG), lead extension and electrode. The PDA allows the experimenter to program the stimulation parameters through a user-friendly graphical interface. The external controller placed on the rat back communicates with PDA via RF telemetry. The IPG generates the biphasic charge-balanced voltage-regulated pulses, which are delivered to the bipolar electrode by the lead extension to achieve chronic ESCS in freely moving rats. A RF carrier from the Class-E amplifier in the external controller provides both data and power for the implanted circuitry through a closely coupled inductive link. The IPG is hermetically packaged using a silicon elastomer and measures 22 mm × 23 mm × 7 mm with a mass of ~3.78 g.
Similar articles
-
A Fully Implantable Stimulator With Wireless Power and Data Transmission for Experimental Investigation of Epidural Spinal Cord Stimulation.IEEE Trans Neural Syst Rehabil Eng. 2015 Jul;23(4):683-92. doi: 10.1109/TNSRE.2015.2396574. Epub 2015 Feb 10. IEEE Trans Neural Syst Rehabil Eng. 2015. PMID: 25680207
-
A fully implanted programmable stimulator based on wireless communication for epidural spinal cord stimulation in rats.J Neurosci Methods. 2012 Mar 15;204(2):341-8. doi: 10.1016/j.jneumeth.2011.10.028. Epub 2011 Nov 6. J Neurosci Methods. 2012. PMID: 22085835
-
A Fully Implantable Miniaturized Liquid Crystal Polymer (LCP)-Based Spinal Cord Stimulator for Pain Control.Sensors (Basel). 2022 Jan 10;22(2):501. doi: 10.3390/s22020501. Sensors (Basel). 2022. PMID: 35062462 Free PMC article.
-
Quadriparesis and spinal cord stimulation: case report.Spine (Phila Pa 1976). 2007 Sep 1;32(19):E565-8. doi: 10.1097/BRS.0b013e31814541dc. Spine (Phila Pa 1976). 2007. PMID: 17762800 Review.
-