Infant flow biphasic nasal continuous positive airway pressure (BP- NCPAP) vs. infant flow NCPAP for the facilitation of extubation in infants' ≤ 1,250 grams: a randomized controlled trial

BMC Pediatr. 2012 Apr 4:12:43. doi: 10.1186/1471-2431-12-43.

Abstract

Background: The use of mechanical ventilation is associated with lung injury in preterm infants and therefore the goal is to avoid or minimize its use. To date there is very little consensus on what is considered the "best non-invasive ventilation mode" to be used post-extubation. The objective of this study was to compare the effectiveness of biphasic nasal continuous positive airway pressure (BP-NCPAP) vs. NCPAP in facilitating sustained extubation in infants ≤ 1,250 grams.

Methods: We performed a randomized controlled trial of BP-NCPAP vs. NCPAP in infants ≤ 1,250 grams extubated for the first time following mechanical ventilation since birth. Infants were extubated using preset criteria or at the discretion of the attending neonatologist. The primary outcome was the incidence of sustained extubation for 7 days. Secondary outcomes included incidence of adverse events and short-term neonatal outcomes.

Results: Sixty-seven infants received BP-NCPAP and 69 NCPAP. Baseline characteristics were similar between groups. The trial was stopped early due to increased use of non-invasive ventilation from birth, falling short of our calculated sample size of 141 infants per group. The incidence of sustained extubation was not statistically different between the BP-NCPAP vs. NCPAP group (67% vs. 58%, P = 0.27). The incidence of adverse events and short-term neonatal outcomes were similar between the two groups (P > 0.05) except for retinopathy of prematurity which was noted to be higher (P = 0.02) in the BP-NCPAP group.

Conclusions: Biphasic NCPAP may be used to assist in weaning from mechanical ventilation. The effectiveness and safety of BP-NCPAP compared to NCPAP needs to be confirmed in a large multi-center trial as our study conclusions are limited by inadequate sample size. CLINICAL TRIALS REGISTRATION #: NCT00308789 SOURCE OF SUPPORT: Grant # 06-06, Physicians Services Incorporated Foundation, Toronto, Canada. Summit technologies Inc. provided additional NCPAP systems and an unrestricted educational grant.Abstract presented at The Society for Pediatric Research Meeting, Baltimore, USA, May 2nd-5th, 2009 and Canadian Paediatric Society Meeting, June 23rd-29th, Ottawa, 2009.

Publication types

  • Comparative Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Airway Extubation* / statistics & numerical data
  • Continuous Positive Airway Pressure / adverse effects
  • Continuous Positive Airway Pressure / instrumentation
  • Continuous Positive Airway Pressure / methods*
  • Early Termination of Clinical Trials
  • Female
  • Humans
  • Infant, Newborn
  • Infant, Premature
  • Infant, Premature, Diseases / epidemiology
  • Infant, Premature, Diseases / therapy
  • Infant, Very Low Birth Weight*
  • Intention to Treat Analysis
  • Logistic Models
  • Male
  • Multivariate Analysis
  • Outcome Assessment, Health Care
  • Ventilator Weaning / methods*

Associated data

  • ClinicalTrials.gov/NCT00308789