Diagnostic accuracy of laxative-free computed tomographic colonography for detection of adenomatous polyps in asymptomatic adults: a prospective evaluation
- PMID: 22586008
- DOI: 10.7326/0003-4819-156-10-201205150-00005
Diagnostic accuracy of laxative-free computed tomographic colonography for detection of adenomatous polyps in asymptomatic adults: a prospective evaluation
Abstract
Background: Colon screening by optical colonoscopy (OC) or computed tomographic colonography (CTC) requires a laxative bowel preparation, which inhibits screening participation.
Objective: To assess the performance of detecting adenomas 6 mm or larger and patient experience of laxative-free, computer-aided CTC.
Design: Prospective test comparison of laxative-free CTC and OC. The CTC included electronic cleansing and computer-aided detection. Optical colonoscopy examinations were initially blinded to CTC results, which were subsequently revealed during colonoscope withdrawal; this method permitted reexamination to resolve discrepant findings. Unblinded OC served as a reference standard. (ClinicalTrials.gov registration number: NCT01200303)
Setting: Multicenter ambulatory imaging and endoscopy centers.
Participants: 605 adults aged 50 to 85 years at average to moderate risk for colon cancer.
Measurements: Per-patient sensitivity and specificity of CTC and first-pass OC for detecting adenomas at thresholds of 10 mm or greater, 8 mm or greater, and 6 mm or greater; per-lesion sensitivity and survey data describing patient experience with preparations and examinations.
Results: For adenomas 10 mm or larger, per-patient sensitivity of CTC was 0.91 (95% CI, 0.71 to 0.99) and specificity was 0.85 (CI, 0.82 to 0.88); sensitivity of OC was 0.95 (CI, 0.77 to 1.00) and specificity was 0.89 (CI, 0.86 to 0.91). Sensitivity of CTC was 0.70 (CI, 0.53 to 0.83) for adenomas 8 mm or larger and 0.59 (CI, 0.47 to 0.70) for those 6 mm or larger; sensitivity of OC for adenomas 8 mm or larger was 0.88 (CI, 0.73 to 0.96) and 0.76 (CI, 0.64 to 0.85) for those 6 mm or larger. The specificity of OC at the threshold of 8 mm or larger was 0.91 and at 6 mm or larger was 0.94. Specificity for OC was greater than that for CTC, which was 0.86 at the threshold of 8 mm or larger and 0.88 at 6 mm or larger (P= 0.02). Reported participant experience for comfort and difficulty of examination preparation was better with CTC than OC.
Limitations: There were 3 CTC readers. The survey instrument was not independently validated.
Conclusion: Computed tomographic colonography was accurate in detecting adenomas 10 mm or larger but less so for smaller lesions. Patient experience was better with laxative-free CTC. These results suggest a possible role for laxative-free CTC as an alternate screening method.
Comment in
-
Update in general internal medicine: evidence published in 2012.Ann Intern Med. 2013 Apr 16;158(8):615-9. doi: 10.7326/0003-4819-158-8-201304160-00101. Ann Intern Med. 2013. PMID: 23579948 No abstract available.
Similar articles
-
Summaries for patients. Screening for colon cancer by using a computed tomographic scan without a laxative.Ann Intern Med. 2012 May 15;156(10):I-36. doi: 10.7326/0003-4819-156-10-201205150-00002. Ann Intern Med. 2012. PMID: 22586019 No abstract available.
-
Computed Tomography Colonography vs Colonoscopy for Colorectal Cancer Surveillance After Surgery.Gastroenterology. 2018 Mar;154(4):927-934.e4. doi: 10.1053/j.gastro.2017.11.025. Epub 2017 Nov 22. Gastroenterology. 2018. PMID: 29174927 Free PMC article. Clinical Trial.
-
A comparison of optical colonoscopy and CT colonography screening strategies in the detection and recovery of subcentimeter adenomas.Am J Gastroenterol. 2010 Dec;105(12):2578-85. doi: 10.1038/ajg.2010.362. Epub 2010 Sep 14. Am J Gastroenterol. 2010. PMID: 20842111
-
Screening for Colorectal Cancer: A Systematic Review for the U.S. Preventive Services Task Force [Internet].Rockville (MD): Agency for Healthcare Research and Quality (US); 2016 Jun. Report No.: 14-05203-EF-1. Rockville (MD): Agency for Healthcare Research and Quality (US); 2016 Jun. Report No.: 14-05203-EF-1. PMID: 27441328 Free Books & Documents. Review.
-
Computed tomographic colonography (CTC): Possibilities and limitations of clinical application in colorectal polyps and cancer.Technol Cancer Res Treat. 2004 Apr;3(2):201-7. doi: 10.1177/153303460400300213. Technol Cancer Res Treat. 2004. PMID: 15059026 Review.
Cited by
-
Acceptance and Preference of Computed Tomographic Colonography and Colonoscopy: Results of a Nationwide Multicenter Comparative Questionnaire Survey in Japan.J Anus Rectum Colon. 2024 Apr 25;8(2):84-95. doi: 10.23922/jarc.2023-025. eCollection 2024. J Anus Rectum Colon. 2024. PMID: 38689783 Free PMC article.
-
Colorectal Cancer: Epidemiology, Risk Factors, and Prevention.Cancers (Basel). 2024 Apr 17;16(8):1530. doi: 10.3390/cancers16081530. Cancers (Basel). 2024. PMID: 38672612 Free PMC article. Review.
-
Warning Signs From the Crypt: Aberrant Protein Glycosylation Marks Opportunities for Early Colorectal Cancer Detection.Clin Transl Gastroenterol. 2023 Jul 1;14(7):e00592. doi: 10.14309/ctg.0000000000000592. Clin Transl Gastroenterol. 2023. PMID: 37141103 Free PMC article. Review.
-
Preference and Experience of Colonic Examination for Participants Presenting to Hospitals with a Positive Fecal Immunochemical Test Result.Patient Prefer Adherence. 2020 Oct 22;14:2017-2025. doi: 10.2147/PPA.S267354. eCollection 2020. Patient Prefer Adherence. 2020. PMID: 33122895 Free PMC article.
-
Cost-effectiveness of surveillance with CT colonography after resection of colorectal cancer.BMJ Open Gastroenterol. 2020 Sep;7(1):e000450. doi: 10.1136/bmjgast-2020-000450. BMJ Open Gastroenterol. 2020. PMID: 32933928 Free PMC article.
Publication types
MeSH terms
Substances
Associated data
Grants and funding
LinkOut - more resources
Full Text Sources
Medical