Ability of code leaders to recall CPR quality errors during the resuscitation of older children and adolescents

Resuscitation. 2012 Dec;83(12):1462-6. doi: 10.1016/j.resuscitation.2012.05.010. Epub 2012 May 24.

Abstract

Aim: Performance of high quality CPR is associated with improved resuscitation outcomes. This study investigates code leader ability to recall CPR error during post-event interviews when CPR recording/audiovisual feedback-enabled defibrillators are deployed.

Patients and methods: Physician code leaders were interviewed within 24h of 44 in-hospital pediatric cardiac arrests to assess their ability to recall if CPR error occurred during the event. Actual CPR quality was assessed using quantitative recording/feedback-enabled defibrillators. CPR error was defined as an overall average event chest compression (CC) rate <95/min, depth < 38 mm, ventilation rate >10/min, or any interruptions in CPR >10s. We hypothesized that code leaders would recall error when it actually occurred ≥ 75% of the time when assisted by audiovisual alerts from a CPR recording feedback-enabled defibrillators (analysis by χ(2)).

Results: 810 min from 44 cardiac arrest events yielded 40 complete data sets (actual and interview); ventilation data was available in 24. Actual CPR error was present in 3/40 events for rate, 4/40 for depth, 32/40 for interruptions >10s, and 17/24 for ventilation frequency. In post-event interviews, code leaders recalled these errors in 0/3 (0%) for rate, 0/4 (0%) for depth, and 19/32 (59%) for interruptions >10s. Code leaders recalled these CPR quality errors less than 75% of the time for rate (p=0.06), for depth (p<0.01), and for CPR interruption (p=0.04). Quantification of errors not recalled: missed rate error median=94 CC/min (IQR 93-95), missed depth error median=36 mm (IQR 35.5-36.5), missed CPR interruption >10s median=18s (IQR 14.4-28.9). Code leaders did recall the presence of excessive ventilation in 16/17 (94%) of events (p=0.07).

Conclusion: Despite assistance by CPR recording/feedback-enabled defibrillators, pediatric code leaders fail to recall important CPR quality errors for CC rate, depth, and interruptions during post-cardiac arrest interviews.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Cardiopulmonary Resuscitation / standards*
  • Child
  • Female
  • Heart Arrest / therapy*
  • Humans
  • Male
  • Medical Errors*
  • Mental Recall*