National trends in primary total hip arthroplasty in extremely young patients: a focus on bearing surface usage
- PMID: 22658430
- DOI: 10.1016/j.arth.2012.04.006
National trends in primary total hip arthroplasty in extremely young patients: a focus on bearing surface usage
Abstract
The purpose of this study was to present national trends in primary total hip arthroplasty (THA) and bearing surface usage for patients 30 years and younger. Using the Healthcare-Cost-and-Utilization-Project Nationwide Inpatient Sample for the years 2006 to 2009, 8919 primary THA discharges (4454 coded by bearing surface) were identified in patients 30 years and younger. The most commonly used bearing surface was metal-on-metal (MoM), representing 37.6% of cases, followed by ceramic-on-ceramic (CoC) (24.6%), metal-on-polyethylene (MoP) (22.1%) and ceramic-on-polyethylene (15.7%). From 2006 to 2009, the percentage of THAs that used hard-on-hard bearing surfaces decreased (MoM: 42.9%-29.4%; CoC: 34.0%-19.7%).This decrease in hard-on-hard bearing surface usage presents a challenge for surgeons treating young patients to find other acceptable durable bearings that do not have the potential problems associated with MoM or CoC.
Copyright © 2012 Elsevier Inc. All rights reserved.
Similar articles
-
National Trends in Primary Total Hip Arthroplasty in Extremely Young Patients: A Focus on Bearing Surface Usage From 2009 to 2012.J Arthroplasty. 2016 Sep;31(9 Suppl):63-8. doi: 10.1016/j.arth.2016.01.061. Epub 2016 Apr 2. J Arthroplasty. 2016. PMID: 27430185
-
Total Hip Arthroplasty Bearing Surface Trends in the United States From 2007 to 2014: The Rise of Ceramic on Polyethylene.J Arthroplasty. 2018 Jun;33(6):1757-1763.e1. doi: 10.1016/j.arth.2017.12.040. Epub 2018 Jan 9. J Arthroplasty. 2018. PMID: 29429883
-
Are Trends in Total Hip Arthroplasty Bearing Surface Continuing to Change? 2007-2015 Usage in a Large Database Cohort.J Arthroplasty. 2017 Dec;32(12):3777-3781. doi: 10.1016/j.arth.2017.07.044. Epub 2017 Aug 3. J Arthroplasty. 2017. PMID: 28887024
-
Advantages and disadvantages of ceramic on ceramic total hip arthroplasty: a review.Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub. 2012 Sep;156(3):204-12. doi: 10.5507/bp.2012.063. Epub 2012 Oct 4. Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub. 2012. PMID: 23069885 Review.
-
State of the art in hard-on-hard bearings: how did we get here and what have we achieved?Expert Rev Med Devices. 2011 Mar;8(2):187-207. doi: 10.1586/erd.10.75. Expert Rev Med Devices. 2011. PMID: 21627555 Review.
Cited by
-
Catastrophic intraoperative failure of a ceramic femoral head.Arthroplast Today. 2021 Oct 8;11:234-238. doi: 10.1016/j.artd.2021.08.017. eCollection 2021 Oct. Arthroplast Today. 2021. PMID: 34692961 Free PMC article.
-
Correlation of Cup Inclination Angle with Liner Wear for Metal-on-polyethylene in Hip Primary Arthroplasty.Orthop Surg. 2017 May;9(2):186-190. doi: 10.1111/os.12337. Epub 2017 May 30. Orthop Surg. 2017. PMID: 28557297 Free PMC article.
-
The Epidemiology and National Trends of Bearing Surface Usage in Primary Total Hip Arthroplasty in Korea.Clin Orthop Surg. 2016 Mar;8(1):29-37. doi: 10.4055/cios.2016.8.1.29. Epub 2016 Feb 13. Clin Orthop Surg. 2016. PMID: 26929796 Free PMC article.
-
Mid-term survivorship and clinical outcomes of cobalt-chrome and oxidized zirconium on highly crosslinked polyethylene.Can J Surg. 2016 Feb;59(1):48-53. doi: 10.1503/cjs.010715. Can J Surg. 2016. PMID: 26812409 Free PMC article.
-
Universal Health Insurance Coverage in Massachusetts Did Not Change the Trajectory of Arthroplasty Use or Costs.Clin Orthop Relat Res. 2016 May;474(5):1090-8. doi: 10.1007/s11999-015-4643-9. Epub 2015 Dec 18. Clin Orthop Relat Res. 2016. PMID: 26683036 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
