Partial descending thoracic aortic replacement for chronic Type B dissection

Heart Lung Circ. 2012 Nov;21(11):740-2. doi: 10.1016/j.hlc.2012.04.017. Epub 2012 May 31.

Abstract

Repair of chronic Type B aortic dissection can be technically challenging. Here we describe a technique for the partial replacement of the descending thoracic aorta that minimises operative risk and avoids full replacement of the thoraco-abdominal aorta. This approach can be considered when there is heterogeneous perfusion of abdominal viscera by the true and false lumens of the chronically dissected aorta.

MeSH terms

  • Adult
  • Aortic Aneurysm, Thoracic / diagnostic imaging
  • Aortic Aneurysm, Thoracic / surgery*
  • Aortic Dissection / diagnostic imaging
  • Aortic Dissection / surgery*
  • Blood Vessel Prosthesis Implantation / methods*
  • Blood Vessel Prosthesis*
  • Chronic Disease
  • Humans
  • Male
  • Radiography